The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Model-based scatter correction for fully 3D PET
Open accessAbstract
A method is presented that directly calculates the mean number of scattered coincidences in data acquired with fully 3D positron emission tomography (PET). This method uses a transmission scan, an emission scan, the physics of Compton scatter, and a mathematical model of the scanner in a forward calculation of the number of events for which one photon has undergone a single Compton interaction. The distribution of events for which multiple Compton interactions have occurred is modelled as a linear transformation of the single-scatter distribution. Computational efficiency is achieved by sampling at rates no higher than those required by the scatter distribution and by implementing the algorithm using look-up tables. Evaluation studies in phantoms with large scatter fractions show that the method yields images with quantitative accuracy equivalent to that of slice-collimated PET in clinically useful times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Bergström, M., Eriksson, L., Bohm, C., Blomqvist, G., & Litton, J. (1983) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198302000-00008 · Cited by 388
Physical performance of a positron tomograph for brain imaging with retractable septa
Spinks, T. J., Jones, T., Bailey, D. L., Townsend, D. W., Grootoonk, S., Bloomfield, P. M., Gilardi, M. C., Casey, M. E., Sipe, B., & Reed, J. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/8/002 · Cited by 293
Continuous-slice PENN-PET: a positron tomograph with volume imaging capability.
Karp, J. S., Muehllehner, G., Mankoff, D. A., Ordoñez, C. E., Ollinger, J. M., Daube-Witherspoon, M. E., Haigh, A. T., & Beerbohm, D. J. (1990) · PubMed · Cited by 236
Self-citationA convolution-subtraction scatter correction method for 3D PET
Bailey, D. L., & Meikle, S. R. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/009 · Cited by 228
Fully three-dimensional reconstruction for a PET camera with retractable septa
Townsend, D. W., Geissbuhler, A., Defrise, M., Hoffman, E. J., Spinks, T. J., Bailey, D. L., Gilardi, M.-C., & Jones, T. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108584 · Cited by 193
3D PET using a Conventional Multislice Tomograph without Septa
Cherry, S. R., Dahlbom, M., & Hoffman, E. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00023 · Cited by 182
Casey, M. E., & Hoffman, E. J. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198609000-00027 · Cited by 175
Casey, M., & Hoffman, E. J. (1986) · PubMed · Cited by 173
Ollinger, J. M. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.276147 · Cited by 88
Self-citation
Cited by
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Vaquero, J. J., & Kinahan, P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040723 · Cited by 383
Parsey, R. V., Oquendo, M. A., Simpson, N. R., Ogden, R. T., Van Heertum, R., Arango, V., & Mann, J. J. (2002) · Brain Research · doi:10.1016/s0006-8993(02)03243-2 · Cited by 311
Relevance of accurate Monte Carlo modeling in nuclear medical imaging
Zaidi, H. (1999) · Medical Physics · doi:10.1118/1.598559 · Cited by 279
Positron Emission Tomography of Monoaminergic Vesicular Binding in Aging and Parkinson Disease
Bohnen, N. I., Albm, R. L., Koeppe, R. A., Wernette, K. A., Kilbourn, M. R., Minoshima, S., & Frey, K. A. (2006) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600276 · Cited by 254
Metadata
- Authors
- Ollinger, J. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1996-01-01
- Volume
- 41
- Issue
- 1
- Pages
- 153-176
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1994156491
- Cited by
- 393
- References
- 11
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Model-based scatter correction for fully 3D PET. https://app.cochat.ai/papers/10.1088/0031-9155/41/1/012
- The paper
- Ollinger, J. M. (1996). Model-based scatter correction for fully 3D PET. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/41/1/012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.