A Comparison of Conventional and Spiral CT: An Experimental Study on the Detection of Spherical Lesions

Kalender, Willi A., Polacin, Arkadiusz, Süss, Christoph·1994·Journal of Computer Assisted Tomography

Abstract

OBJECTIVE: It is accepted that spiral CT scanning may offer significant advantages in a number of clinical applications. There is still some concern with respect to image quality, however, since slice sensitivity profiles are slightly broadened due to the table motion. We carried out theoretical analysis, phantom measurements, and computer simulations to evaluate and to compare contrast and spatial resolution for conventional and for spiral scanning. Special emphasis was put on the task of detecting spherical lesions. MATERIALS AND METHODS: For standard test objects that measure only resolution in the scan plane, no significant difference between conventional and spiral scanning was observed. We therefore designed a phantom setup that allowed us to place spheres of arbitrary diameter and contrast in arbitrary positions to test three-dimensional (3D) resolution. RESULTS: For conventional CT, both lesion contrast and the degree of spatial separation of lesions observed depend on the relation of the start position of the scan series to the random location of a sphere or lesion. Spiral CT offers space-invariant resolution due to its continuous scanning. Small lesion contrast may be improved by up to a factor of 1.8 when compared with conventional CT since slices can be centered retrospectively. Measurements and simulations were in excellent agreement. CONCLUSION: We conclude that spiral CT can offer improved 3D contrast and spatial resolution. To exploit these advantages, images should be reconstructed in spiral CT at increments of less than half the distance traveled during one 360 degrees tube rotation. With four to five images per such interval, usually equal to the slice width, results very close to the theoretical optimum are achieved. Many of the presented considerations and results apply to other slice imaging modalities like MRI in analogous fashion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-199403000-00001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Kalender, W. A., Polacin, A., & Süss, C.
Venue
Journal of Computer Assisted Tomography
Published
1994-03
Volume
18
Issue
2
Pages
167-176
ISSN
0363-8715 (ISSN-L)
OpenAlex
W1996585576
Cited by
182
References
0
FWCI
19.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Conventional and Spiral CT: An Experimental Study on the Detection of Spherical Lesions. https://app.cochat.ai/papers/10.1097/00004728-199403000-00001
The paper
Kalender, W. A., Polacin, A., & Süss, C. (1994). A Comparison of Conventional and Spiral CT: An Experimental Study on the Detection of Spherical Lesions. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199403000-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.