A Comparison of Conventional and Spiral CT: An Experimental Study on the Detection of Spherical Lesions
Abstract
OBJECTIVE: It is accepted that spiral CT scanning may offer significant advantages in a number of clinical applications. There is still some concern with respect to image quality, however, since slice sensitivity profiles are slightly broadened due to the table motion. We carried out theoretical analysis, phantom measurements, and computer simulations to evaluate and to compare contrast and spatial resolution for conventional and for spiral scanning. Special emphasis was put on the task of detecting spherical lesions. MATERIALS AND METHODS: For standard test objects that measure only resolution in the scan plane, no significant difference between conventional and spiral scanning was observed. We therefore designed a phantom setup that allowed us to place spheres of arbitrary diameter and contrast in arbitrary positions to test three-dimensional (3D) resolution. RESULTS: For conventional CT, both lesion contrast and the degree of spatial separation of lesions observed depend on the relation of the start position of the scan series to the random location of a sphere or lesion. Spiral CT offers space-invariant resolution due to its continuous scanning. Small lesion contrast may be improved by up to a factor of 1.8 when compared with conventional CT since slices can be centered retrospectively. Measurements and simulations were in excellent agreement. CONCLUSION: We conclude that spiral CT can offer improved 3D contrast and spatial resolution. To exploit these advantages, images should be reconstructed in spiral CT at increments of less than half the distance traveled during one 360 degrees tube rotation. With four to five images per such interval, usually equal to the slice width, results very close to the theoretical optimum are achieved. Many of the presented considerations and results apply to other slice imaging modalities like MRI in analogous fashion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mutic, S., Palta, J. R., Butker, E. K., Das, I. J., Huq, M. S., Loo, L.-N. D., Salter, B. J., McCollough, C. H., & Van Dyk, J. (2003) · Medical Physics · doi:10.1118/1.1609271 · Cited by 344
Application of the Suchey-Brooks method to three-dimensional imaging of the pubic symphysis
Telmon, N., Gaston, A., Chemla, P., Blanc, A., Joffre, F., & Rougé, D. (2005) · Journal of Forensic Sciences · doi:10.1520/jfs2004326 · Cited by 101
Metadata
- Authors
- Kalender, W. A., Polacin, A., & Süss, C.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1994-03
- Volume
- 18
- Issue
- 2
- Pages
- 167-176
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1996585576
- Cited by
- 182
- References
- 0
- FWCI
- 19.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Comparison of Conventional and Spiral CT: An Experimental Study on the Detection of Spherical Lesions. https://app.cochat.ai/papers/10.1097/00004728-199403000-00001
- The paper
- Kalender, W. A., Polacin, A., & Süss, C. (1994). A Comparison of Conventional and Spiral CT: An Experimental Study on the Detection of Spherical Lesions. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199403000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.