CoChat

Normal Enhancement of the Small Bowel: Evaluation with Spiral CT

Horton, Karen M., Eng, John, Fishman, Elliot K. · 2000 · Journal of Computer Assisted Tomography
Cited by 79

The DOI matches its Crossref record.

Abstract

PURPOSE: The purpose of this work was to determine normal contrast enhancement of the small bowel with biphasic spiral CT, using water as oral contrast agent. METHOD: Biphasic spiral CT was performed in 50 healthy patients undergoing evaluation as potential renal donors. All patients received 500 ml of water as oral contrast agent and 150 ml of Omnipaque 350 administered by mechanical injector at a rate of 3 ml/s. Dual phase CT of the abdomen was performed in each patient. Acquisition of early phase images began 30 s after the start of the intravenous injection, and portal phase images were obtained 60 s after initiation of the contrast agent injection. Attenuation measurements (in Hounsfield units) were obtained from the wall of the small bowel (duodenum, jejunum, ileum) in both the arterial and the portal phases. RESULTS: During the arterial phase, the mean (95% confidence interval) attenuation of the duodenum, jejunum, and ileum was 120 (+/- 5), 119 (+/- 5), and 118 (+/- 5) HU, respectively. During the portal phase, the average attenuation of the duodenum, jejunum, and ileum was 111 (+/- 4), 111 (+/- 3), and 107 (+/- 3) HU, respectively. There was no statistically significant difference between the attenuation of the duodenum, jejunum, or ileum within either the arterial or the portal venous phases. There was a statistically significant difference in small bowel enhancement between the arterial and portal venous phases. CONCLUSION: There is no important variation in small bowel attenuation during the 30 and 60 s scanning phases. This study serves as a normal reference that may be helpful when spiral CT is used to evaluate ischemic bowel or inflammatory small bowel diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-200001000-00014

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 79

Metadata

Authors
Horton, K. M., Eng, J., & Fishman, E. K.
Venue
Journal of Computer Assisted Tomography
Published
2000-01
Volume
24
Issue
1
Pages
67-71
ISSN
0363-8715 (ISSN-L)
OpenAlex
W1981296374
Cited by
79
References
0
FWCI
4.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Normal Enhancement of the Small Bowel: Evaluation with Spiral CT. https://app.cochat.ai/papers/10.1097/00004728-200001000-00014
The paper
Horton, K. M., Eng, J., & Fishman, E. K. (2000). Normal Enhancement of the Small Bowel: Evaluation with Spiral CT. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-200001000-00014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.