Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 363

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Crohn Disease: Mural Attenuation and Thickness at Contrast-enhanced CT Enterography—Correlation with Endoscopic and Histologic Findings of Inflammation

Bodily, Kale D., Fletcher, Joel G., Solem, Craig A., Johnson, C. Daniel, Fidler, Jeff L., Barlow, John M., Bruesewitz, Michael R., McCollough, Cynthia H., Sandborn, William J., Loftus, Edward V., Harmsen, William S., Crownhart, Brian S.·2006·Radiology

Abstract

PURPOSE: To determine retrospectively if quantitative measures of small-bowel mural attenuation and thickness at computed tomographic (CT) enterography correlate with endoscopic and histologic findings of small-bowel inflammation and to estimate the performance of these measures in predicting inflammatory Crohn disease. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant retrospective study, which was conducted with patient informed consent. CT enterography data in 96 patients (31 male patients and 65 female patients) who underwent ileoscopy with or without biopsy were examined for CT signs of active Crohn disease. The most highly enhancing segment of terminal ileum and a normal-appearing ileal loop were identified. After it was confirmed that semiautomated software could accurately measure mural attenuation and thickness, the selected terminal ileal and normal-appearing (control) ileal loops were examined (20 automated measurements at each location) to quantify mural attenuation and wall thickness. Results were compared with endoscopy and histology reports by using logistic regression analysis and receiver operating characteristic curves. RESULTS: Quantitative measures of terminal ileal mural attenuation and wall thickness correlated significantly with active Crohn disease (P < .001). Small-bowel wall thickness was not a significant factor after attenuation was taken into account. A threshold attenuation value with a sensitivity of 90% (18 of 20) for definite Crohn disease (compared with a sensitivity of 80% [16 of 20] for radiologist assessment) was selected. In patients who underwent ileal biopsy, threshold attenuation had a sensitivity identical to that of ileoscopy (81% [26 of 32]; 95% confidence interval: 64%, 93%) in predicting histologic inflammation. CONCLUSION: Quantitative measures of mural attenuation and wall thickness at CT enterography correlate highly with ileoscopic and histologic findings of inflammatory Crohn disease. Quantitative measures of mural attenuation are sensitive markers of small bowel inflammation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2382041159

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 363

Metadata

Authors
Bodily, K. D., Fletcher, J. G., Solem, C. A., Johnson, C. D., Fidler, J. L., Barlow, J. M., Bruesewitz, M. R., McCollough, C. H., Sandborn, W. J., Loftus, E. V., Harmsen, W. S., & Crownhart, B. S.
Venue
Radiology
Published
2006-02
Volume
238
Issue
2
Pages
505-516
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1965200384
Cited by
363
References
9
FWCI
16.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Crohn Disease: Mural Attenuation and Thickness at Contrast-enhanced CT Enterography—Correlation with Endoscopic and Histologic Findings of Inflammation. https://app.cochat.ai/papers/10.1148/radiol.2382041159
The paper
Bodily, K. D., Fletcher, J. G., Solem, C. A., Johnson, C. D., Fidler, J. L., Barlow, J. M., Bruesewitz, M. R., McCollough, C. H., Sandborn, W. J., Loftus, E. V., Harmsen, W. S., & Crownhart, B. S. (2006). Crohn Disease: Mural Attenuation and Thickness at Contrast-enhanced CT Enterography—Correlation with Endoscopic and Histologic Findings of Inflammation. Radiology. https://doi.org/10.1148/radiol.2382041159

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.