The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
Abstract
The background underpinning the clinical use of ultrashort echo-time (UTE) pulse sequences for imaging tissues or tissue components with short T2s is reviewed. Tissues properties are discussed, and tissues are divided into those with a majority of short T2 relaxation components and those with a minority. Features of the basic physics relevant to UTE imaging are described including the fact that when the radiofrequency pulse duration is of the order T2, rotation of tissue magnetization into the transverse plane is incomplete. Consequences of the broad line-width of short T2 components are also discussed including their partial saturation by off-resonance fat suppression pulses as well as multislice and multiecho imaging. The need for rapid data acquisition of the order T2 is explained. The basic UTE pulse sequence with its half excitation pulse and radial imaging from the center of k-space is described together with options that suppress fat and/or long T2 components. Image interpretation is discussed. Clinical features of the imaging of cortical bone, tendons, ligaments, menisci, and periosteum as well as brain, liver, and spine are illustrated. Short T2 components in all of these tissues may show high signals. Possible future developments are outlined as are technical limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Magnetization transfer in MRI: a review
Henkelman, R. M., Stanisz, G. J., & Graham, S. J. (2001) · NMR in Biomedicine · doi:10.1002/nbm.683 · Cited by 921
Fibrocartilage in tendons and ligaments — an adaptation to compressive load
BENJAMIN, M., & RALPHS, J. R. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19340481.x · Cited by 787
Anisotropy of NMR properties of tissues
Henkelman, R. M., Stanisz, G. J., Kim, J. K., & Bronskill, M. J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320508 · Cited by 424
Magnetic Resonance Imaging of Short T2 Components in Tissue
Gatehouse, P. D., & Bydder, G. M. (2003) · Clinical Radiology · doi:10.1053/crad.2003.1157 · Cited by 317
Self-citationTissue Sodium Concentration in Human Brain Tumors as Measured with 23 Na MR Imaging
Ouwerkerk, R., Bleich, K. B., GILLEN, J. S., Pomper, M. G., & Bottomley, P. A. (2003) · Radiology · doi:10.1148/radiol.2272020483 · Cited by 301
Magnetization Transfer and T2 Relaxation Components in Tissue
Harrison, R., Bronskill, M. J., & Henkelman, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330406 · Cited by 140
MR imaging of articular cartilage of the knee: new methods using ultrashort TEs.
Gold, G. E., Thedens, D. R., Pauly, J. M., Fechner, K. P., Bergman, G. A., Beaulieu, C. F., & Macovski, A. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.5.9574589 · Cited by 117
Characterization of atherosclerosis with a 1.5‐T imaging system
Gold, G. E., Pauly, J. M., Glover, G. H., et al. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030216 · Cited by 91
Relaxation times and microstructures
Fenrich, F. R., Beaulieu, C., & Allen, P. S. (2001) · NMR in Biomedicine · doi:10.1002/nbm.685 · Cited by 64
Cited by
Benjamin, M., Toumi, H., Ralphs, J. R., Bydder, G., Best, T. M., & Milz, S. (2006) · Journal of Anatomy · doi:10.1111/j.1469-7580.2006.00540.x · Cited by 898
Self-citationQuantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489
MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Keereman, V., Fierens, Y., Broux, T., De Deene, Y., Lonneux, M., & Vandenberghe, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065425 · Cited by 442
Diagnosis of osteoarthritis: Imaging
Braun, H. J., & Gold, G. E. (2012) · Bone · doi:10.1016/j.bone.2011.11.019 · Cited by 402
Metadata
- Authors
- Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 2003-11
- Volume
- 27
- Issue
- 6
- Pages
- 825-846
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1968795335
- Cited by
- 717
- References
- 11
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging. https://app.cochat.ai/papers/10.1097/00004728-200311000-00001
- The paper
- Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M. (2003). Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-200311000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.