Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The background underpinning the clinical use of ultrashort echo-time (UTE) pulse sequences for imaging tissues or tissue components with short T2s is reviewed. Tissues properties are discussed, and tissues are divided into those with a majority of short T2 relaxation components and those with a minority. Features of the basic physics relevant to UTE imaging are described including the fact that when the radiofrequency pulse duration is of the order T2, rotation of tissue magnetization into the transverse plane is incomplete. Consequences of the broad line-width of short T2 components are also discussed including their partial saturation by off-resonance fat suppression pulses as well as multislice and multiecho imaging. The need for rapid data acquisition of the order T2 is explained. The basic UTE pulse sequence with its half excitation pulse and radial imaging from the center of k-space is described together with options that suppress fat and/or long T2 components. Image interpretation is discussed. Clinical features of the imaging of cortical bone, tendons, ligaments, menisci, and periosteum as well as brain, liver, and spine are illustrated. Short T2 components in all of these tissues may show high signals. Possible future developments are outlined as are technical limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Magnetization transfer in MRI: a review
Henkelman, R. M., Stanisz, G. J., & Graham, S. J. (2001) · NMR in Biomedicine · doi:10.1002/nbm.683 · Cited by 921
Fibrocartilage in tendons and ligaments — an adaptation to compressive load
BENJAMIN, M., & RALPHS, J. R. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19340481.x · Cited by 787
Anisotropy of NMR properties of tissues
Henkelman, R. M., Stanisz, G. J., Kim, J. K., & Bronskill, M. J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320508 · Cited by 424
Tissue Sodium Concentration in Human Brain Tumors as Measured with 23 Na MR Imaging
Ouwerkerk, R., Bleich, K. B., GILLEN, J. S., Pomper, M. G., & Bottomley, P. A. (2003) · Radiology · doi:10.1148/radiol.2272020483 · Cited by 331
Magnetic Resonance Imaging of Short T2 Components in Tissue
Gatehouse, P. D., & Bydder, G. M. (2003) · Clinical Radiology · doi:10.1053/crad.2003.1157 · Cited by 317
Self-citationMagnetization Transfer and T2 Relaxation Components in Tissue
Harrison, R., Bronskill, M. J., & Henkelman, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330406 · Cited by 158
MR imaging of articular cartilage of the knee: new methods using ultrashort TEs.
Gold, G. E., Thedens, D. R., Pauly, J. M., Fechner, K. P., Bergman, G. A., Beaulieu, C. F., & Macovski, A. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.5.9574589 · Cited by 117
Characterization of atherosclerosis with a 1.5‐T imaging system
Gold, G. E., Pauly, J. M., Glover, G. H., Moretto, J. C., Macovski, A., & Herfkens, R. J. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030216 · Cited by 92
Relaxation times and microstructures
Fenrich, F. R. E., Beaulieu, C., & Allen, P. S. (2001) · NMR in Biomedicine · doi:10.1002/nbm.685 · Cited by 62
Cited by
Benjamin, M., Toumi, H., Ralphs, J. R., Bydder, G., Best, T. M., & Milz, S. (2006) · Journal of Anatomy · doi:10.1111/j.1469-7580.2006.00540.x · Cited by 898
Self-citationQuantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489
MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Keereman, V., Fierens, Y., Broux, T., De Deene, Y., Lonneux, M., & Vandenberghe, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065425 · Cited by 442
Diagnosis of osteoarthritis: Imaging
Braun, H. J., & Gold, G. E. (2012) · Bone · doi:10.1016/j.bone.2011.11.019 · Cited by 402
An overview of kidney stone imaging techniques
Brisbane, W., Bailey, M. R., & Sorensen, M. D. (2016) · Nature Reviews Urology · doi:10.1038/nrurol.2016.154 · Cited by 391
A review of substitute CT generation for MRI-only radiation therapy
Edmund, J. M., & Nyholm, T. (2017) · Radiation Oncology · doi:10.1186/s13014-016-0747-y · Cited by 378
R2* magnetic resonance imaging of the liver in patients with iron overload
Hankins, J. S., McCarville, M. B., Loeffler, R. B., Smeltzer, M. P., Onciu, M., Hoffer, F. A., Li, C.-S., Wang, W. C., Ware, R. E., & Hillenbrand, C. M. (2009) · Blood · doi:10.1182/blood-2008-12-191643 · Cited by 372
Radiotherapy planning using MRI
Schmidt, M. A., & Payne, G. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/r323 · Cited by 357
Fast and quiet MRI using a swept radiofrequency
Idiyatullin, D., Corum, C., Park, J.-Y., & Garwood, M. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.05.014 · Cited by 353
Berker, Y., Franke, J., Salomon, A., Palmowski, M., Donker, H. C. W., Temur, Y., Mottaghy, F. M., Kuhl, C., Izquierdo-Garcia, D., Fayad, Z. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092577 · Cited by 344
Johansson, A., Karlsson, M., & Nyholm, T. (2011) · Medical Physics · doi:10.1118/1.3578928 · Cited by 324
Johnstone, E., Wyatt, J. J., Henry, A. M., Short, S. C., Sebag-Montefiore, D., Murray, L., Kelly, C. G., McCallum, H. M., & Speight, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.08.043 · Cited by 317
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
UTE imaging in the musculoskeletal system
Chang, E. Y., Du, J., & Chung, C. B. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24713 · Cited by 276
Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted sampling
Rahmer, J., Börnert, P., Groen, J., & Bos, C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20868 · Cited by 273
Zero TEMR bone imaging in the head
Wiesinger, F., Sacolick, L. I., Menini, A., Kaushik, S. S., Ahn, S., Veit‐Haibach, P., Delso, G., & Shanbhag, D. D. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25545 · Cited by 242
“Ultrashort echo time (UTE) pulse sequences with center-out k-space sampling starting immediately following the radio frequency (RF) excitation enable fastenough MR data acquisition to capture the rapidly decaying bone signals (1,2).”
BackgroundMethodInfluentialHsu, S.-H., Cao, Y., Huang, K., Feng, M., & Balter, J. M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8419 · Cited by 233
“Recently, ultrashort echo time (UTE) sequences were developed to visualize tissues with very short T2, such as bone (Robson et al 2003, Catana et al 2010, Keereman et al 2010).”
BackgroundResultQualitative and quantitative ultrashort‐TE MRI of cortical bone
Du, J., & Bydder, G. M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2906 · Cited by 159
“T2* quantification The T2* value of cortical bone has been measured with UTE acquisitions at progressively increasing TEs (52).”
BackgroundMethodSelf-citationFormalin tissue fixation biases myelin – sensitive MRI
Seifert, A. C., Umphlett, M., Hefti, M., Fowkes, M., & Xu, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27821 · Cited by 44
Metadata
- Authors
- Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 2003-11
- Volume
- 27
- Issue
- 6
- Pages
- 825-846
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1968795335
- Cited by
- 717
- References
- 11
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.