Clinical evaluation of semiautomatic and automatic devices for home blood pressure measurement: comparison between cuff-oscillometric and microphone methods
The DOI matches its Crossref record.
Abstract
The accuracy and reliability of blood pressure (BP) values were evaluated by comparing values obtained with eight automatic or semiautomatic devices designed for home BP measurement (four microphone devices based on the Korotkoff-sound technique and four cuff-oscillometric devices) with those obtained by the auscultatory method, using a standard mercury sphygmomanometer. Systolic blood pressure (SBP) values obtained using the microphone devices coincided well with those obtained by the auscultatory method. However, these devices produced a certain proportion of errors in the measurement of diastolic blood pressure (DBP), sometimes resulting in recordings at least 25mmHg higher than those obtained by the standard method. The most frequent causes of this phenomenon were an auscultatory (silent) gap and a weak Korotkoff sound after phase IV. A microphone device using a condenser microphone built into the manometer displayed comparatively good acoustic characteristics for determining DBP. All cuff-oscillometric devices demonstrated minimal mean differences and a constant s.d. of mean difference for DBP, with no great differences from the auscultatory method. However, mean differences and s.d.s in SBP measurements using cuff-oscillometric devices were relatively greater than those obtained using some of the microphone devices. Furthermore, the direction of the mean differences in measurements from those obtained with the auscultatory method differed. The error in relation to the auscultatory method tended to be reproducible in the same subjects with both the microphone and the cuff-oscillometric devices. These results indicate that practitioners should select the most appropriate method and/or device by taking into account the factors which may cause measurement error in relation to the auscultatory method in each subject, and should then evaluate, at least once, the difference in BP values obtained using the auscultatory method and using the device. In future, home blood pressure measurement devices for determination of SBP should employ a microphone method, while a method which combines a microphone with a cuff-oscillometric device, thereby compensating for the disadvantage of the Korotkoff-sound signal with the pulse wave signal, should be recommended for measurement of DBP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ohkubo, T., Imai, Y., Tsuji, I., Nagai, K., Kato, J., Kikuchi, N., Nishiyama, A., Aihara, A., Sekino, M., Kikuya, M., et al. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00010 · Cited by 741
Self-citationOhkubo, T., Kikuya, M., Metoki, H., Asayama, K., Obara, T., Hashimoto, J., Totsune, K., Hoshi, H., Satoh, H., & Imai, Y. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.070 · Cited by 575
Self-citationPrinciples and Techniques of Blood Pressure Measurement
Ogedegbe, G., & Pickering, T. (2010) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 554
Kikuya, M., Ohkubo, T., Asayama, K., Metoki, H., Obara, T., Saito, S., Hashimoto, J., Totsune, K., Hoshi, H., Satoh, H., et al. (2005) · Hypertension · doi:10.1161/01.hyp.0000152079.04553.2c · Cited by 417
Self-citationJananese Society of Hypertension (JSH) Guidelines for Self-Monitoring of Blood Pressure at Home
IMAI, Y., OTSUKA, K., KAWANO, Y., SHIMADA, K., HAYASHI, H., TOCHIKUBO, O., MIYAKAWA, M., & FUKIYAMA, K. (2003) · Hypertension Research · doi:10.1291/hypres.26.771 · Cited by 309
Self-citation
Metadata
- Authors
- Imai, Y., Abe, K., Sasaki, S., Minami, N., Munakata, M., Sakuma, H., Hashimoto, J., Sekino, H., Imai, K., & Yoshinaga, K.
- Venue
- Journal of Hypertension
- Published
- 1989-12
- Volume
- 7
- Issue
- 12
- Pages
- 983-990
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2055457636
- Cited by
- 125
- References
- 0
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical evaluation of semiautomatic and automatic devices for home blood pressure measurement: comparison between cuff-oscillometric and microphone methods. https://app.cochat.ai/papers/10.1097/00004872-198912000-00009
- The paper
- Imai, Y., Abe, K., Sasaki, S., Minami, N., Munakata, M., Sakuma, H., Hashimoto, J., Sekino, H., Imai, K., & Yoshinaga, K. (1989). Clinical evaluation of semiautomatic and automatic devices for home blood pressure measurement: comparison between cuff-oscillometric and microphone methods. Journal of Hypertension. https://doi.org/10.1097/00004872-198912000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.