Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 309

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Jananese Society of Hypertension (JSH) Guidelines for Self-Monitoring of Blood Pressure at Home

Open access
IMAI, Yutaka, OTSUKA, Kuniaki, KAWANO, Yuhei, SHIMADA, Kazuyuki, HAYASHI, Hiroshi, TOCHIKUBO, Osamu, MIYAKAWA, Masaaki, FUKIYAMA, Koshiro·2003·Hypertension Research

Abstract

UNLABELLED: Home blood pressure (BP) measurements are indispensable for the improvement of hypertension management in medical practice as well as for the recognition of hypertension in the population. The Working Group for Establishment of Guidelines for Measurement Procedures of Self-Monitoring of Blood Pressure at Home of the Japanese Society of Hypertension has established standards for all techniques and procedures of home BP measurements. The recommendations are as follows. RECOMMENDATION: 1) Arm-cuff devices based on the cuff-oscillometric method that have been validated officially, and the accuracy of which has been confirmed in each individual, should be used for home BP measurement. 2) The BP should be measured at the upper arm. Finger-cuff devices and wrist-cuff devices should not be used for home BP measurements. 3) Devices for home BP measurement should be adapted to the American Association for Medical Instrumentation (AAMI) standards and the British Hypertension Society (BHS) guidelines. In addition, the difference between the BP measured by the auscultatory method and that measured using the device should be within 5 mmHg in each individual. The home measurement device should be validated before use, and at regular intervals during use. 4) Home BP should be monitored under the following conditions. The morning measurement should be made within 1 h after waking, after micturition, sitting after 1 to 2 min of rest, before drug ingestion, and before breakfast. The evening measurement should be made just before going to bed, sitting after 1 to 2 min of rest. 5) Home BP should be measured at least once in the morning and once in the evening. 6) All home BP measurements should be documented without selection, together with the date, time, and pulse rate. Use of devices with a printer or an integrated circuit memory is useful to avoid selection bias. 7) The home BP in the morning and that in the evening should be averaged separately for a certain period. The first measurement on each occasion should be used for totaling. 8) Home BP values averaged for a certain period indicate hypertension when 135/80 mmHg and over and definite hypertension when 135/85 mmHg and over. Normotension is defined as less than 125/80 mmHg and definite normotension as less than 125/75 mmHg. Home BP measurements based on these guidelines can be considered an appropriate tool for clinical decision-making, and it is hoped that these guidelines will serve to reduce confusion and confirm the place of home BP measurement in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1291/hypres.26.771

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 309

Metadata

Authors
IMAI, Y., OTSUKA, K., KAWANO, Y., SHIMADA, K., HAYASHI, H., TOCHIKUBO, O., MIYAKAWA, M., & FUKIYAMA, K.
Venue
Hypertension Research
Published
2003
Volume
26
Issue
10
Pages
771-782
ISSN
  • 0916-9636 (ISSN-L)
  • 1348-4214
OpenAlex
W2105052825
Cited by
309
References
40
FWCI
10.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Jananese Society of Hypertension (JSH) Guidelines for Self-Monitoring of Blood Pressure at Home. https://app.cochat.ai/papers/10.1291/hypres.26.771
The paper
IMAI, Y., OTSUKA, K., KAWANO, Y., SHIMADA, K., HAYASHI, H., TOCHIKUBO, O., MIYAKAWA, M., & FUKIYAMA, K. (2003). Jananese Society of Hypertension (JSH) Guidelines for Self-Monitoring of Blood Pressure at Home. Hypertension Research. https://doi.org/10.1291/hypres.26.771

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.