Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: implications for studies on antihypertensive drugs
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To assess the reproducibility of average hourly blood pressure values obtained by 24-h non-invasive ambulatory monitoring. PATIENTS: Fifteen outpatients with essential hypertension. In all subjects antihypertensive treatment was withdrawn for 4 weeks before and during the 4 weeks of the study. METHODS: The 24-h blood pressure was monitored by a SpaceLabs 5300 device (four readings per hour during the day and three readings per hour during the night) twice, at a 4-week interval. Systolic (SBP) and diastolic blood pressure (DBP) were averaged for each hour and for the whole 24-h period, and hourly and 24-h reproducibility was quantified by the standard deviation of the mean difference (SDD) between the values obtained in the two recordings. RESULTS: The SDD of hourly SBP and DBP was much greater than that of the 24-h values and ranged widely between the hours of recording. The SDD of hourly SBP and DBP were also variably greater than the SDD of the 24-h value in another 14 untreated essential hypertensives in whom 24-h ambulatory blood pressure was monitored intra-arterially twice at a 4-week interval to calculate hourly average blood pressure on thousands rather than on three or four values per hour. CONCLUSION: Reproducibility is less for hourly than for 24-h average blood pressure. This feature (which probably depends on behavioural differences between two recordings) suggests that ambulatory blood pressure measurement partly loses its advantages for reproducibility and reduction in trial size if the results are analysed over hourly periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Self-citationDaskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Blood Pressure · doi:10.3109/08037051.2013.812549 · Cited by 426
Self-citationKario, K., Kanegae, H., Tomitani, N., Okawara, Y., Fujiwara, T., Yano, Y., Hoshide, S., & on behalf of the J-HOP Study Group (2019) · Hypertension · doi:10.1161/hypertensionaha.118.12740 · Cited by 167
Metadata
- Authors
- Mancia, G., Omboni, S., Parati, G., Trazzi, S., & Mutti, E.
- Venue
- Journal of Hypertension
- Published
- 1992-12
- Volume
- 10
- Issue
- 12
- Pages
- 1531-1535
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W1982151116
- Cited by
- 72
- References
- 0
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: implications for studies on antihypertensive drugs. https://app.cochat.ai/papers/10.1097/00004872-199210120-00014
- The paper
- Mancia, G., Omboni, S., Parati, G., Trazzi, S., & Mutti, E. (1992). Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: implications for studies on antihypertensive drugs. Journal of Hypertension. https://doi.org/10.1097/00004872-199210120-00014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.