Long-term reproducibility of ambulatory blood pressure
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To compare the reproducibility of ambulatory and office blood pressure readings in established hypertensive subjects when studies are repeated at extended time intervals. SUBJECTS: Twenty-five hypertensive patients (office diastolic blood pressure > or = 90 mmHg) who were off antihypertensive therapy for at least 4 weeks and had repeat office and ambulatory blood pressures at least 3 months apart under similar study conditions. METHODS: On the same day, patients underwent office blood pressure readings measured by mercury column sphygmomanometry and then by ambulatory blood pressure monitoring. Ambulatory blood pressure monitoring was done for 24 h, and awake and sleep periods were divided according to a diary kept by each patient. A second study was performed in an identical manner at a mean +/- SD interval of 23 +/- 24 months (range 3-80, median 15). The agreement between studies was assessed by correlation coefficients, coefficients of variation and standard deviation of the differences (SDD). RESULTS: There were no significant differences in office, 24-h, awake and sleep mean blood pressures between the two studies. Mean 24-h systolic and diastolic blood pressures were 16 and 14 mmHg lower, respectively, than office blood pressure values. Correlation coefficients were significantly higher for 24-h ambulatory blood pressure than office blood pressure, whereas the SDD between visits was significantly lower for 24-h ambulatory blood pressure than office blood pressure. CONCLUSIONS: These data demonstrate that long-term reproducibility of ambulatory blood pressure is superior to that for office measurement. One implication of this finding is that, in long-term clinical pharmacology trials utilizing ambulatory blood pressure, fewer subjects would be required than for studies that used office blood pressure end-points.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ohkubo, T., Hozawa, A., Nagaie, K., Kikuya, M., Tsujia, I., Itoc, S., Satoh, H., Hisamichi, S., & Imaid, Y. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018070-00005 · Cited by 241
(2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.2.161 · Cited by 233
Circadian variation of blood pressure: The basis for the chronotherapy of hypertension
Hermida, R. C., Ayala, D. E., & Portaluppi, F. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.08.003 · Cited by 221
White, W. B., Weber, M. A., Sica, D., Bakris, G. L., Perez, A., Cao, C., & Kupfer, S. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.163402 · Cited by 216
Self-citationOhkubo, T., Imai, Y., Tsuji, I., Nagai, K., Ito, S., Satoh, H., & Hisamichi, S. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.255 · Cited by 206
Metadata
- Authors
- Mansoor, G. A., McCabe, E. J., & White, W. B.
- Venue
- Journal of Hypertension
- Published
- 1994-06
- Volume
- 12
- Issue
- 6
- Pages
- 703???708
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2010486854
- Cited by
- 117
- References
- 0
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term reproducibility of ambulatory blood pressure. https://app.cochat.ai/papers/10.1097/00004872-199406000-00011
- The paper
- Mansoor, G. A., McCabe, E. J., & White, W. B. (1994). Long-term reproducibility of ambulatory blood pressure. Journal of Hypertension. https://doi.org/10.1097/00004872-199406000-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.