Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Reference Values for 24-Hour Ambulatory Blood Pressure Monitoring Based on a Prognostic Criterion: The Ohasama Study

Open access
Ohkubo, Takayoshi, Imai, Yutaka, Tsuji, Ichiro, Nagai, Kenichi, Ito, Sadayoshi, Satoh, Hiroshi, Hisamichi, Shigeru·1998·Hypertension

Abstract

Abstract —Although reference values for ambulatory blood pressure (ABP) monitoring have been investigated in several population studies, these values were derived from cross-sectional observations and were based merely on the statistical distribution of blood pressure values. Therefore, we conducted a prospective cohort study to identify reference values for 24-hour ABP in relation to prognosis. We obtained measurements of 24-hour ABP for 1542 subjects (565 men) aged 40 years and over in a general population of a rural Japanese community and then followed-up their survival status. There were 117 deaths during the follow-up period (mean, 6.2 years). The association between baseline 24-hour ABP values and mortality, examined by the Cox proportional hazards regression model adjusted for possible confounding factors, showed a better fit with a second-degree equation than with a first-degree equation. On the basis of the results of this analysis, we identified the following reference values as the optimal blood pressure ranges that predict the best prognosis: 120 to 133 mm Hg for systolic blood pressure and 65 to 78 mm Hg for diastolic blood pressure. 24-Hour ABP values >134/79 mm Hg and <119/64 mm Hg were related to increased risks for cardiovascular and noncardiovascular mortality, respectively. This is the first report to propose reference values for 24-hour ABP based on a prognostic criterion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.32.2.255

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Ohkubo, T., Imai, Y., Tsuji, I., Nagai, K., Ito, S., Satoh, H., & Hisamichi, S.
Venue
Hypertension
Published
1998-08
Volume
32
Issue
2
Pages
255-259
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2103937406
Cited by
206
References
3
FWCI
7.42
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reference Values for 24-Hour Ambulatory Blood Pressure Monitoring Based on a Prognostic Criterion: The Ohasama Study. https://app.cochat.ai/papers/10.1161/01.hyp.32.2.255
The paper
Ohkubo, T., Imai, Y., Tsuji, I., Nagai, K., Ito, S., Satoh, H., & Hisamichi, S. (1998). Reference Values for 24-Hour Ambulatory Blood Pressure Monitoring Based on a Prognostic Criterion: The Ohasama Study. Hypertension. https://doi.org/10.1161/01.hyp.32.2.255

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.