Prediction of the actual awake and asleep blood pressures by various methods of 24 h pressure analysis
Abstract
OBJECTIVE: To assess the relationships of daytime and night-time blood pressures and the day-night pressure differences, obtained by various analytical methods, with the actual awake and asleep pressures and the awake-asleep pressure difference. METHODS: Ambulatory blood pressure was successfully monitored by use of the SpaceLabs 90202 device in 91 healthy young men during a weekend, when they went to bed and awoke at variable and often unusual times. The actual 'awake' and 'asleep' blood pressures were calculated on the basis of these times, noted by the subjects. The 24 h recordings were further analysed by use of two clock time-independent methods (square-wave fitting; cumulative sum analysis) and by one 'wide' (A) and one 'narrow' (B) fixed-time method (daytime: 0700-2200 h or 1000-2000 h; night-time: 2200-0700 h or 0000-0600 h, for methods A and B, respectively). RESULTS: In the total study population, square-wave fitting (+1.1 +/- 1.5 mmHg, mean +/- SD) and cumulative sum analysis (2.4 +/- 1.9 mmHg) overestimated the actual awake systolic blood pressure and underestimated the asleep pressure (-0.7 +/- 1.7 and -1.8 +/- 1.8 mmHg, respectively). The fixed-time techniques underestimated the awake pressure (-2.6 +/- 3.1 and -0.2 +/- 3.2 mmHg for methods A and B, respectively) and overestimated the asleep pressure by +4.9 +/- 5.5 and +2.7 +/- 6.1 mmHg, respectively. The actual awake-asleep pressure difference was overestimated by square-wave fitting (+1.8 +/- 1.9 mmHg) and more so by cumulative sum analysis (+4.2 +/- 2.5 mmHg); the underestimation by the fixed time approach averaged -3.0 +/- 8.4 mmHg with method B and amounted to -7.5 +/- 8.3 mmHg with method A. Overall, the SD of the various differences between the estimated and the actual awake and asleep pressures, and consequently the limits of agreement, were larger for the fixed-time methods than for the clock time-independent techniques. In the 47 subjects who went to bed before 2400 h and awoke between 0600 and 1000 h, the results of the clock time-independent methods were similar to the results in the total study population, whereas the deviations of the fixed time pressures from the actual awake and asleep blood pressures were considerably reduced. The results were similar for diastolic blood pressure. CONCLUSIONS: Clock time-independent methods, particularly square-wave fitting, can predict the actual awake and asleep blood pressures and the awake-asleep pressure differences with reasonable accuracy and the results are independent of the awake-asleep pattern of the subjects. However, fixed-time methods are only reliable when the subjects go to bed and arise within well-defined periods, and yield more accurate results when the morning and evening phases are excluded from the daytime and night-time periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Self-citationEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationPrognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Self-citation
Metadata
- Authors
- Fagard, R., Brguljan, J., Thijs, L., & Staessen, J.
- Venue
- Journal of Hypertension
- Published
- 1996-05
- Volume
- 14
- Issue
- 5
- Pages
- 557-563
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2034262083
- Cited by
- 172
- References
- 0
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prediction of the actual awake and asleep blood pressures by various methods of 24 h pressure analysis. https://app.cochat.ai/papers/10.1097/00004872-199605000-00003
- The paper
- Fagard, R., Brguljan, J., Thijs, L., & Staessen, J. (1996). Prediction of the actual awake and asleep blood pressures by various methods of 24 h pressure analysis. Journal of Hypertension. https://doi.org/10.1097/00004872-199605000-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.