Limitations of the difference between clinic and daytime blood pressure as a surrogate measure of the ‘white-coat’ effect

Parati, Gianfranco, Omboni, Stefano, Staessen, Jan, Thijs, Lutgarde, Fagard, Robert, Ulian, Luisa, Mancia, Giuseppe · 1998 · Journal of Hypertension
Cited by 81

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The difference between clinic and ambulatory average daytime blood pressures is frequently taken as a surrogate measure of the 'white-coat effect' (i.e. the pressor reaction triggered in the patient by the physician's visit). OBJECTIVE: To assess the reproducibility of this difference and its relationship with clinic and average ambulatory daytime blood pressure levels. DESIGN AND METHODS: These issues were addressed with two large groups of subjects in whom both clinic and ambulatory blood pressures were measured, namely 783 outpatients with systolic and diastolic essential hypertension [Group 1, aged 50.8+/-9.4 years (mean +/- SD)], participating in standardized Italian trials of antihypertensive drugs, and 506 elderly patients (group 2, age 71+/-7 years) with isolated systolic hypertension, participating in the European Syst-Eur trial. RESULTS: The clinic-daytime blood pressure difference for the essential systolic and diastolic hypertensive patients (group 1) was 13.6+/-14.3 mmHg for systolic and 9.1+/-8.6 mmHg for diastolic blood pressure (P always < 0.01). This difference for the elderly patients with isolated systolic hypertension (group 2) was 21.2+/-16.0 mmHg for systolic and only 1.3+/-10.2 mmHg for diastolic blood pressure (P < 0.01 and P < 0.05, respectively). In both studies little or no systematic clinic-daytime difference could be observed for heart rate. The reproducibility of the clinic-daytime blood pressure difference, tested for 108 essential systolic and diastolic hypertensive patients from group 1 and 128 isolated systolic hypertensives from group 2, was invariably lower than that both of daytime and of clinic blood pressure values. Finally, the clinic-daytime blood pressure difference was progressively higher for increasing levels of clinic blood pressure and progressively lower for higher levels of ambulatory daytime blood pressure. CONCLUSIONS: Thus, the clinic-daytime blood pressure difference has a limited reproducibility; depends not only on clinic but also on daytime average blood pressure, which means that its size is a function of the blood pressure criteria employed for selection of the patients in a trial; and is never associated with a systematic clinic-daytime difference in heart rate, which further questions its use as a reliable surrogate measure of the true pressor response induced in the patient by the doctor's visit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-199816010-00005

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 81

Metadata

Authors
Parati, G., Omboni, S., Staessen, J., Thijs, L., Fagard, R., Ulian, L., & Mancia, G.
Venue
Journal of Hypertension
Published
1998-01
Volume
16
Issue
1
Pages
23-29
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2396305006
Cited by
81
References
3
FWCI
4.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Limitations of the difference between clinic and daytime blood pressure as a surrogate measure of the ‘white-coat’ effect. https://app.cochat.ai/papers/10.1097/00004872-199816010-00005
The paper
Parati, G., Omboni, S., Staessen, J., Thijs, L., Fagard, R., Ulian, L., & Mancia, G. (1998). Limitations of the difference between clinic and daytime blood pressure as a surrogate measure of the ‘white-coat’ effect. Journal of Hypertension. https://doi.org/10.1097/00004872-199816010-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.