CoChat

Prediction of left ventricular geometry by clinic, pre-dialysis and 24-h ambulatory BP monitoring in hemodialysis patients

Zoccali, Carmine, Mallamaci, Francesca, Tripepi, Giovanni, Benedetto, Frank A., Cottini, Emilio, Giacone, Giuseppe, Malatino, Lorenzo · 1999 · Journal of Hypertension
Cited by 95

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Arterial hypertension is an established risk factor for left ventricular hypertrophy (LVH) in the uremic population. However, whether 24-h monitoring is a better predictor of LVH than clinic blood pressure and routine pre-dialysis measurements in these patients is still undefined. METHODS: This problem was studied in 64 nondiabetic hemodialysis patients without heart failure. The echocardiographic study as well as the clinic and 24-h ambulatory blood pressure (BP) measurements were performed during the day off-dialysis. Pre-dialysis arterial pressure was calculated as the average value of the 12 routine recordings taken during the month preceding the study. RESULTS: In multivariate models, including also sex, body mass index, hematocrit and serum cholesterol, pre-dialysis systolic, diastolic and pulse pressures were the only independent BP determinants of heart geometry. Twenty-four hour ambulatory BP monitoring (ABPM) did add significant (but weak) information to the prediction of left ventricular internal dimension, i.e. it increased by 9% (P = 0.01) the variance already explained by pre-dialysis diastolic BP and other significant covariates. However, 24-h ABPM did not add any significant and independent explanatory information to the corresponding pre-dialysis measurements for the posterior wall and interventricular septum measurements, and for left ventricular mass (-0.6 to +3.9%; average +1.1%). CONCLUSIONS: In dialysis patients, pre-dialysis BP is at least as strong a predictor of left ventricular mass as 24-h ambulatory monitoring. Thus, the average of 12 routine pre-dialysis measurements may be used to predict heart geometry in dialysis patients without any loss of information in comparison with 24-h ambulatory monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-199917120-00013

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 95

Metadata

Authors
Zoccali, C., Mallamaci, F., Tripepi, G., Benedetto, F. A., Cottini, E., Giacone, G., & Malatino, L.
Venue
Journal of Hypertension
Published
1999-12
Volume
17
Issue
12
Pages
1751-1758
ISSN
0263-6352 (ISSN-L)
OpenAlex
W126742549
Cited by
95
References
2
FWCI
4.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of left ventricular geometry by clinic, pre-dialysis and 24-h ambulatory BP monitoring in hemodialysis patients. https://app.cochat.ai/papers/10.1097/00004872-199917120-00013
The paper
Zoccali, C., Mallamaci, F., Tripepi, G., Benedetto, F. A., Cottini, E., Giacone, G., & Malatino, L. (1999). Prediction of left ventricular geometry by clinic, pre-dialysis and 24-h ambulatory BP monitoring in hemodialysis patients. Journal of Hypertension. https://doi.org/10.1097/00004872-199917120-00013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.