CoChat

The importance of high-frequency paced breathing in spectral baroreflex sensitivity assessment

Frederiks, Joost, Swenne, Cees A., TenVoorde, Ben J., Honzíkovaá, Nataša, Levert, Jeroen V., Maan, Arie C., Schalij, Martin J., Bruschke, Albert V.G. · 2000 · Journal of Hypertension
Cited by 70

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Computation of the low-frequency (LF) blood pressure variability (BPV) to heart rate variability (HRV) transfer-index is a common method to assess baroreflex sensitivity (BRS), tacitly assuming that all LF-HRV is caused by baroreflex feedback of LF-BPV. However, respiration may also cause HRV by mechanisms not involving the baroreflex. Application of narrow-band (controlled) high-frequency breathing would keep such non-baroreflex-mediated HRV best out of the LF band. Spontaneous breathing, because of its broad-band character, might cause extra, non-baroreflex-mediated, HRV in the LF band, while paced LF breathing would even concentrate most non-baroreflex-mediated HRV in the LF band. Our study addresses the likely resulting BRS overestimation. DESIGN: We recorded HRV and BPV in 20 healthy young subjects in the sitting position. We varied the sympathovagal balance by gradual leg-lowering from horizontal till 60 degrees . At each angle the subjects performed controlled 0.10 Hz, spontaneous, and controlled 0.25 Hz respiration. RESULTS: Resting BRS values were 15.5(7.2), 13.1 (3.7), and 11.6(6.2) ms/mmHg, respectively. Both the 15/min and the free breathing values differed significantly, P< 0.01 and P= 0.04, from the 6/min breathing value. With lowered legs, the BRS values were 8.2(3.4), 8.3(2.9), and 8.3(3.4) ms/mmHg, respectively. CONCLUSION: Controlled 6/min breathing caused significant BRS overestimation under resting conditions. For the group, spontaneous respiration yielded acceptable BRS values, but individual BRS values deviated sometimes considerably. Conversely, with gravitational load, the respiratory pattern had only minor impact on BRS. Our results demonstrate that the risk of an overestimated BRS value is realistic as long as respiration is not controlled and of high-frequency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-200018110-00015

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 70

Metadata

Authors
Frederiks, J., Swenne, C. A., TenVoorde, B. J., Honzíkovaá, N., Levert, J. V., Maan, A. C., Schalij, M. J., & Bruschke, A. V. G.
Venue
Journal of Hypertension
Published
2000-11
Volume
18
Issue
11
Pages
1635-1644
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2321201805
Cited by
70
References
3
FWCI
1.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The importance of high-frequency paced breathing in spectral baroreflex sensitivity assessment. https://app.cochat.ai/papers/10.1097/00004872-200018110-00015
The paper
Frederiks, J., Swenne, C. A., TenVoorde, B. J., Honzíkovaá, N., Levert, J. V., Maan, A. C., Schalij, M. J., & Bruschke, A. V. G. (2000). The importance of high-frequency paced breathing in spectral baroreflex sensitivity assessment. Journal of Hypertension. https://doi.org/10.1097/00004872-200018110-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.