Pulse wave velocity as endpoint in large-scale intervention trial. The Complior® study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the ability of an antihypertensive therapy to improve arterial stiffness as assessed by aortic pulse wave velocity (PWV) in a large population of hypertensive patients. SETTING: Sixty-nine healthcare centres, private and institutional (19 countries). PATIENTS: Subjects aged 18-79 years, with essential hypertension. A total of 2,187 patients were enrolled; 1,703 (52% male) completed the study: mean age = 50 +/- 12 years; mean baseline systolic/diastolic blood pressure (S/D BP) = 158 +/- 15/98 +/- 7 mmHg; mean baseline carotid-femoral PWV = 11.6 +/- 2.4 m/s. INTERVENTIONS: Patients were treated for 6 months, starting with perindopril (angiotensin converting enzyme (ACE) inhibitor) 4 mg once daily (OD), increased to 8 mg OD, and combined to diuretic (indapamide 2.5 mg OD) if BP was uncontrolled (> 140/90 mmHg). RESULTS: It was feasible to measure carotid-femoral PWV using the automatic device Complior at inclusion, 2 and 6 months, along with conventional BP assessments in a population of 1,703 patients. Significant decreases (P < 0.001) in BP (systolic: -23.7 +/- 16.8, diastolic: -14.6 +/- 10 mmHg), and carotid-femoral PWV (-1.1 +/- 1.4 m/s) were obtained at 2 and 6 months. CONCLUSIONS: The Complior Study is the first study to show the feasibility of a large-scale intervention trial using PWV as the endpoint in hypertensive patients. Adequate results may be obtained using an automatic device and rigorous criteria for assessment. A long-term controlled intervention study is needed to confirm the results of the present uncontrolled trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Asmar, R., Benetos, A., Topouchian, J., Laurent, P., Pannier, B., Brisac, A.-M., Target, R., & Levy, B. I. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.485 · Cited by 1,376
Self-citation
Cited by
YAMASHINA, A., TOMIYAMA, H., TAKEDA, K., TSUDA, H., ARAI, T., HIROSE, K., KOJI, Y., HORI, S., & YAMAMOTO, Y. (2002) · Hypertension Research · doi:10.1291/hypres.25.359 · Cited by 1,623
Blumenthal, J. A. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.470 · Cited by 578
Drager, L. F., Bortolotto, L. A., Figueiredo, A. C., Krieger, E. M., & Lorenzi-Filho, G. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-500oc · Cited by 559
Scherrer, U., Rimoldi, S. F., Rexhaj, E., Stuber, T., Duplain, H., Garcin, S., de Marchi, S. F., Nicod, P., Germond, M., Allemann, Y., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.071183 · Cited by 295
Effects of cranberry juice consumption on vascular function in patients with coronary artery disease
Dohadwala, M. M., Holbrook, M., Hamburg, N. M., Shenouda, S. M., Chung, W. B., Titas, M., Kluge, M. A., Wang, N., Palmisano, J., Milbury, P. E., et al. (2011) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.110.004242 · Cited by 272
Utility of automated brachial ankle pulse wave velocity measurements in hypertensive patients
Munakata, M. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00918-x · Cited by 269
de Luca, N., Asmar, R. G., London, G. M., O'Rourke, M. F., & Safar, M. E. (2004) · Journal of Hypertension · doi:10.1097/01.hjh.0000125448.28861.fc · Cited by 192
Self-citationShahin, Y., Khan, J. A., & Chetter, I. (2012) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2011.12.005 · Cited by 187
Scuteri, A., Tesauro, M., Appolloni, S., Preziosi, F., Brancati, A. M., & Volpe, M. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3280895b55 · Cited by 181
Association of Assisted Reproductive Technologies With Arterial Hypertension During Adolescence
Meister, T. A., Rimoldi, S. F., Soria, R., von Arx, R., Messerli, F. H., Sartori, C., Scherrer, U., & Rexhaj, E. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.060 · Cited by 161
“Large-artery stiffness was assessed noninvasively by measuring carotidfemoral PWV with the Complior device (Artech Medical, Pantin, France) according to international guidelines (17) and as previously described (4,18).”
MethodOKURA, T., WATANABE, S., KURATA, M., MANABE, S., KORESAWA, M., IRITA, J., ENOMOTO, D., MIYOSHI, K.-I., FUKUOKA, T., & HIGAKI, J. (2007) · Hypertension Research · doi:10.1291/hypres.30.335 · Cited by 161
Increased pulse-wave velocity in patients with anxiety: implications for autonomic dysfunction
Yeragani, V. K., Tancer, M., Seema, K. P., Josyulab, K., & Desai, N. (2006) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2005.10.011 · Cited by 48
De Luca, M., Iacono, O., Valente, V., Giardino, F., Crisci, G., Lettieri, M., Marra, A., Giallauria, F., & Oliviero, U. (2022) · Journal of Basic and Clinical Physiology and Pharmacology · doi:10.1515/jbcpp-2021-0193 · Cited by 9
Metadata
- Authors
- Asmar, R., Topouchian, J., Pannier, B., Benetos, A., & Safar, M.
- Venue
- Journal of Hypertension
- Published
- 2001-04
- Volume
- 19
- Issue
- 4
- Pages
- 813-818
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2314616432
- Cited by
- 151
- References
- 1
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.