Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Pulsatile blood pressure component as predictor of mortality in hypertension: a meta-analysis of clinical trial control groups

Open access
Gasowski, Jerzy, Fagard, Robert H., Staessen, Jan A., Grodzicki, Tomasz, Pocock, Stuart, Boutitie, Florent, Gueyffier, François, Boissel, Jean-Pierre · 2002 · Journal of Hypertension

Abstract

OBJECTIVE: Although current guidelines rest exclusively on the measurement of systolic and diastolic blood pressures, the arterial pressure wave is more precisely described as consisting of a pulsatile (pulse pressure) and a steady (mean pressure) component. This study explored the independent roles of pulse pressure and mean pressure as predictors of mortality in a wide range of patients with hypertension. DESIGN AND METHODS: This meta-analysis, based on individual patient data, has combined results from the control groups of seven randomized clinical trials conducted in patients with systolo-diastolic or isolated systolic hypertension. The relative hazard rates associated with pulse pressure and mean pressure were calculated using Cox's proportional hazard regression models with stratification for the seven trials and with adjustment for sex, age, smoking and the other pressure. RESULTS: A 10 mmHg wider pulse pressure at baseline, which corresponds to approximately one-half of its standard deviation, was independently associated with an increase in risk by 6% for total mortality (P = 0.001), 7% for cardiovascular mortality (P = 0.01), and 7% for fatal coronary accidents (P = 0.03). The corresponding increase in risk of fatal stroke was similar (+6%, P = 0.27) but there were too few strokes to reach statistical significance. In similar analyses, mean pressure was not identified as an independent predictor of these outcomes. Significant interactions of pulse pressure or mean pressure with age suggested that the prognostic power of pulse pressure for fatal stroke was more important at higher age (P = 0.04), whereas the prognostic power of mean pressure for coronary mortality was greatest in the young (P = 0.01). CONCLUSIONS: In hypertensive patients pulse pressure, not mean pressure, is associated with an increased risk of fatal events. This appears to be true in a broad range of patients with hypertension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-200201000-00021

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 161

Metadata

Authors
Gasowski, J., Fagard, R. H., Staessen, J. A., Grodzicki, T., Pocock, S., Boutitie, F., Gueyffier, F., & Boissel, J.-P.
Venue
Journal of Hypertension
Published
2002-01
Volume
20
Issue
1
Pages
145-151
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2161025784
Cited by
161
References
3
FWCI
1.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulsatile blood pressure component as predictor of mortality in hypertension: a meta-analysis of clinical trial control groups. https://app.cochat.ai/papers/10.1097/00004872-200201000-00021
The paper
Gasowski, J., Fagard, R. H., Staessen, J. A., Grodzicki, T., Pocock, S., Boutitie, F., Gueyffier, F., & Boissel, J.-P. (2002). Pulsatile blood pressure component as predictor of mortality in hypertension: a meta-analysis of clinical trial control groups. Journal of Hypertension. https://doi.org/10.1097/00004872-200201000-00021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.