CoChat

Reversed white-coat hypertension: definition, mechanisms and prognostic implications

Mancia, Giuseppe · 2002 · Journal of Hypertension
Cited by 37

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In this issue of the journal, Wing et al. [1] properly mention that the condition they refer to as ‘reversed white-coat hypertension’ had already been described in previous studies. They also emphasize, however, the main novel finding of their study. While in previous studies ‘reversed white-coat hypertension’ was regarded as rare, in their study, this condition was found to have a noticeable prevalence (i.e. to characterize from approximately one-third to one-half of the hypertensive population based on systolic and diastolic blood pressure measurements, respectively). This means that when physicians find an elevated office blood pressure, the possibility that daytime ambulatory values are greater rather than lower (as it may seem logical from the distribution of the two pressures in the general population) (Fig. 1) [2] should be regarded as by no means remote. Interestingly, this is the case also in the elderly hypertensive individuals studied by Wing et al. in which the average difference between the higher office and the lower ambulatory blood pressure values is particularly pronounced [3].Fig. 1: Frequency distribution of the office systolic and diastolic blood pressure values (SBP and DBP, respectively) in the PAMELA population versus (a) home blood pressure, (b) 24 h average blood pressure, (c) daytime blood pressure and (d) night-time blood pressure. The upper limit of normality office blood pressure (140/90 mmHg) and the corresponding values on the home, 24 h, day and night blood pressure distribution curves are indicated. The portion of the distribution curves to the right of the upper normality values are indicated by dark or shaded areas. Adapted with permission [2]. The ‘reversed white coat hypertension’ addressed by Wing et al. [1] leads to discussion of at least three issues on which evidence is limited and thus speculation is inevitable. The first issue concerns the mechanisms responsible for making daytime average blood pressure greater than office blood pressure, at variance to what happens in the majority of hypertensive individuals. Wing et al. [1] discuss this at length and offer several findings of interest. They found that ‘reverse white-coat hypertension’ was related to cigarette smoking and more frequent in individuals on antihypertensive treatment or in whom office blood pressure was closer to the threshold classically dividing hypertension from normotension. This can be explained by the results obtained in previous studies. These have shown that (i) cigarette smoking elicits a marked and prolonged (up to 30 min) pressor response [4–7]. In heavy smokers, this can substantially elevate daytime average blood pressure [7,8] and bring it above office values which are normally taken after a few hours abstinence from smoking. (ii) In the general population, the difference between office and average ambulatory blood pressure is positively related to the former value [9] and, in hypertensive patients, it becomes less during antihypertensive treatment [10,11]. This means a greater theoretical chance for ambulatory blood pressure to exceed office blood pressure, which is exactly what Wing et al. have demonstrated [1]. The second issue is what should be the best definition of the condition characterized by an average ambulatory blood pressure greater than office blood pressure. My opinion is that ‘reversed white-coat hypertension’ is not appropriate because it focuses on the involvement of an alerting reaction and leads people to think that the one elicited by the monitoring device may be greater that the one brought about by measuring blood pressure in the clinical environment. We have shown, however, that, except for a short-lasting initial period, automatic ambulatory blood pressure measurements do not trigger any alerting reaction and pressor response [12]. We have also shown that the difference between the greater office and the lower ambulatory blood pressure is not related to the true pressor response to blood pressure measurements by a doctor, which was accurately quantified by having the patients on beat-to-beat prolonged blood pressure monitoring [13]. This led the WHO/ISH Guidelines to not use the term ‘white-coat hypertension’ for this condition but the less mechanistic and more descriptive term ‘isolated office hypertension’ [14], a similar semantic caution being probably desirable also for the opposite condition (greater ambulatory than office blood pressure) described by Wing et al. [1]. This would avoid a conceptual inconsistency: namely, that the difference between office and ambulatory blood pressure obviously also depends on the latter and that an ambulatory value lower, similar or greater than the office value may be brought about by the effect on daily blood pressure of behaviours (physical activity, work, smoking, etc.) which have nothing to do with the alerting reaction to blood pressure measurements by a doctor or a nurse (Fig. 2).Fig. 2: Schematics showing that the di

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-200204000-00006

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 37

Metadata

Authors
Mancia, G.
Venue
Journal of Hypertension
Published
2002-04
Volume
20
Issue
4
Pages
579-581
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2007246421
Cited by
37
References
2
FWCI
1.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reversed white-coat hypertension: definition, mechanisms and prognostic implications. https://app.cochat.ai/papers/10.1097/00004872-200204000-00006
The paper
Mancia, G. (2002). Reversed white-coat hypertension: definition, mechanisms and prognostic implications. Journal of Hypertension. https://doi.org/10.1097/00004872-200204000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.