The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Patient Rating of Wrist Pain and Disability: A Reliable and Valid Measurement Tool
Abstract
OBJECTIVE: The goal of this study was to develop a reliable and valid tool for quantifying patient-rated wrist pain and disability. DESIGN: Survey, tool development, reliability, and validity study. SETTING: Upper extremity unit. PARTICIPANTS: One hundred members of the International Wrist Investigators were surveyed by mail to assist in development of the scale. Patients with distal radius (n = 64) or scaphoid (n = 35) fractures were enrolled in a reliability study, and 101 patients with distal radius fractures were enrolled in a validity study. INTERVENTION: Information from the expert survey, biomechanical literature, and patient interviews was used as a basis for item generation and definition of structural limitations for a scale that would be practical in the clinic. Patients with distal radius or scaphoid fractures completed the Patient-Rated Wrist Evaluation (PRWE) on two occasions to determine test-retest reliability. Patients with distal radius fractures (n = 101) completed the PRWE and the SF-36 and were tested with traditional impairment measures at baseline and at two, three, and six months after fracture to determine construct and criterion validity. MAIN OUTCOME MEASURES: Reliability coefficients (ICCs) and validity correlations (Pearson product moment correlations). RESULTS: Patient opinions on pain and on ability to do activities of daily living and work were thought to be the most important dimensions to include in subjective outcome tools. Brevity and simplicity were seen as essential in the clinic environment. A fifteen-item questionnaire (the PRWE) was designed to measure wrist pain and disability. Test-retest reliability was excellent (ICCs > 0.90). Validity assessment demonstrated that the instrument detected significant differences over time (p < 0.01) and was appropriately correlated with alternate forms of assessing parameters of pain and disability. CONCLUSIONS: The PRWE provides a brief, reliable, and valid measure of patient-rated pain and disability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · PubMed · Cited by 33,716
The MOS 36-ltem Short-Form Health Survey (SF-36): I. Conceptual Framework and Item Selection
Ware, J. E., & Sherbourne, C. D. (1992) · Medical Care · doi:10.1097/00005650-199206000-00002 · Cited by 30,033
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Hudak, P. L., Amadio, P. C., Bombardier, C., Beaton, D., Cole, D., Davis, A., Hawker, G., Katz, J. N., Makela, M., Marx, R. G., et al. (1996) · American Journal of Industrial Medicine · doi:10.1002/(sici)1097-0274(199606)29:6<602::aid-ajim4>3.0.co;2-l · Cited by 5,025
Reliability and validity of grip and pinch strength evaluations
Mathiowetz, V., Weber, K., Volland, G., & Kashman, N. (1984) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(84)80146-x · Cited by 1,857
An objective and standardized test of hand function.
Jebsen, R. H., Taylor, N. F., Trieschmann, R. B., Trotter, M. J., & Howard, L. (1969) · PubMed · Cited by 1,705
Development of a Scale for Patient Rating of Wrist Pain and Disability
MacDermid, J. C. (1996) · Journal of Hand Therapy · doi:10.1016/s0894-1130(96)80076-7 · Cited by 405
Self-citationEpidemiology of Fractures of the Forearm: A Biomechanical Investigation of Bone Strength
Alffram, P.-A., & Bauer, G. C. H. (1962) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196244010-00009 · Cited by 336
Incidence of Colles' fracture in a North American community.
Owen, R. A., Melton, L. J., Johnson, K. A., Ilstrup, D. M., & Riggs, B. L. (1982) · American Journal of Public Health · doi:10.2105/ajph.72.6.605 · Cited by 309
Sickness impact profile: The state of the art of a generic functional status measure
de Bruin, A. F., de Witte, L. P., Stevens, F., & Diederiks, J. P. M. (1992) · Social Science & Medicine · doi:10.1016/0277-9536(92)90240-q · Cited by 242
Cited by
Measuring the whole or the parts?
Beaton, D. E., Katz, J. N., Fossel, A. H., Wright, J. G., Tarasuk, V., & Bombardier, C. (2001) · Journal of Hand Therapy · doi:10.1016/s0894-1130(01)80043-0 · Cited by 1,306
Aspenberg, P., Genant, H. K., Johansson, T., Nino, A. J., See, K., Krohn, K., García-Hernández, P. A., Recknor, C. P., Einhorn, T. A., Dalsky, G. P., et al. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090731 · Cited by 513
Schmitt, J. S., & Di Fabio, R. P. (2004) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2004.02.007 · Cited by 487
MacDermid, J. C., Richards, R. S., Donner, A., Bellamy, N., & Roth, J. H. (2000) · The Journal of Hand Surgery · doi:10.1053/jhsu.2000.jhsu25a0330 · Cited by 404
Self-citationOutcome evaluation measures for wrist and hand – which one to choose?
Changulani, M., Okonkwo, U., Keswani, T., & Kalairajah, Y. (2008) · International Orthopaedics · doi:10.1007/s00264-007-0368-z · Cited by 271
Metadata
- Authors
- MacDermid, J. C., Turgeon, T., Richards, R. S., Beadle, M., & Roth, J. H.
- Venue
- Journal of Orthopaedic Trauma
- Published
- 1998-11
- Volume
- 12
- Issue
- 8
- Pages
- 577-586
- ISSN
- 0890-5339 (ISSN-L)
- OpenAlex
- W1981658722
- Cited by
- 857
- References
- 12
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient Rating of Wrist Pain and Disability: A Reliable and Valid Measurement Tool. https://app.cochat.ai/papers/10.1097/00005131-199811000-00009
- The paper
- MacDermid, J. C., Turgeon, T., Richards, R. S., Beadle, M., & Roth, J. H. (1998). Patient Rating of Wrist Pain and Disability: A Reliable and Valid Measurement Tool. Journal of Orthopaedic Trauma. https://doi.org/10.1097/00005131-199811000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.