No Effect of Low-Intensity Ultrasound on Healing Time of Intramedullary Fixed Tibial Fractures
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether stimulation with low-intensity ultrasound will reduce the radiologic healing time of fresh tibial shaft fractures fixed with a reamed and statically locked intramedullary rod. DESIGN: Prospective, randomized, double blinded, and placebo controlled. PATIENTS AND METHODS: Thirty-two adult patients were included, fifteen in the active ultrasound group and seventeen in the placebo group. They all used an ultrasound device twenty minutes daily for seventy-five days without knowing whether it was active or inactive. Standardized radiographs were taken every third week until healing and at six and twelve months. All radiographs were assessed blinded and independently by a radiologist and an orthopaedic surgeon. The codes were not broken until all fractures had healed and all radiographs had been evaluated. RESULTS: The time until the first visible callus averaged 40+/-3 days for the active group and 37+/-3 days for the placebo (p=0.44). The healing time, defined as radiologic bridging of three cortices, was on average 155+/-22 days (median 113 days) for the active treatment group and 125+/-11 days (median 112 days) for the placebo group (p=0.76) as assessed by the radiologist and 128+/-13 days for the active group and 114+/-9 days for the placebo group (p=0.40) as evaluated by the orthopaedic surgeon. CONCLUSION: We conclude that low-intensity ultrasound treatment did not shorten healing time in fresh tibial fractures treated with a reamed and statically locked intramedullary nail. Our results are not in accordance with previous findings reporting reduced healing time in nonoperatively treated tibial shaft fractures when subjected to ultrasound.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlled mechanical stimulation in the treatment of tibial fractures
KENWRIGHT, J., & GOODSHIP, A. E. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198904000-00006 · Cited by 373
Cited by
GOVENDER, S., CSIMMA, C., GENANT, H. K., & VALENTIN-OPRAN, A. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200212000-00001 · Cited by 1,308
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
JONES, A. L., BUCHOLZ, R. W., BOSSE, M. J., MIRZA, S. K., LYON, T. R., WEBB, L. X., POLLAK, A. N., GOLDEN, J. D., & VALENTIN-OPRAN, A. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200607000-00002 · Cited by 444
Variability in the Assessment of Fracture-Healing in Orthopaedic Trauma Studies
Corrales, L. A., Morshed, S., Bhandari, M., & Miclau, T. (2008) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.01580 · Cited by 415
The Use of Low-Intensity Ultrasound to Accelerate the Healing of Fractures
Rubin, C., Bolander, M., Ryaby, J. P., & Hadjiargyrou, M. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200102000-00015 · Cited by 412
Metadata
- Authors
- Emami, A., Petrén-Mallmin, M., & Larsson, S.
- Venue
- Journal of Orthopaedic Trauma
- Published
- 1999-05
- Volume
- 13
- Issue
- 4
- Pages
- 252-257
- ISSN
- 0890-5339 (ISSN-L)
- OpenAlex
- W1992682352
- Cited by
- 118
- References
- 1
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: No Effect of Low-Intensity Ultrasound on Healing Time of Intramedullary Fixed Tibial Fractures. https://app.cochat.ai/papers/10.1097/00005131-199905000-00005
- The paper
- Emami, A., Petrén-Mallmin, M., & Larsson, S. (1999). No Effect of Low-Intensity Ultrasound on Healing Time of Intramedullary Fixed Tibial Fractures. Journal of Orthopaedic Trauma. https://doi.org/10.1097/00005131-199905000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.