Reproducibility of Laser Doppler Imaging of Skin Blood Flow as a Tool to Assess Endothelial Function
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Endothelial dysfunction might be an important and early event in the pathogenesis of major cardiovascular diseases. Therefore, the evaluation of endothelial function in humans may be of great clinical relevance. Usual methods for that purpose are either invasive and/or technically demanding. In the dermal microcirculation, endothelial function may be assessed noninvasively from the laser Doppler measurement of increases in blood flow after either the transdermal application of acetylcholine by iontophoresis, or the release of transient arterial occlusion (reactive hyperemia). An endothelium-independent response may be provided by the iontophoresis of sodium nitroprusside. This approach is notable for technical simplicity, but of uncertain reproducibility. Sixteen young, healthy, nonsmoking males were examined in the fasting state. Changes in skin blood flow were measured with a laser Doppler imager during the iontophoresis of acetylcholine and sodium nitroprusside, as well as during reactive hyperemia, on two different days, at each of two different sites on the volar face of the forearm. Nonspecific effects related to the stimulation of terminal nerve fibers by the iontophoretic current were suppressed by prior surface anesthesia. The iontophoresis of acetylcholine and sodium nitroprusside induced a seven- to eightfold increase in dermal blood flow. The corresponding figure for peak reactive hyperemia was approximately fourfold. The mean coefficients of variation of responses recorded on different days, on the same site, in the same individual were <10% for iontophoresis of acetylcholine and for peak reactive hyperemia, and between 10 and 20% for iontophoresis of sodium nitroprusside. This day-to-day variation was significantly smaller than the site-to-site variation (p < 0.01 for all three responses). Endothelium-dependent and -independent responses of dermal blood flow evaluated with laser Doppler imaging are highly reproducible from day to day, at least in healthy nonsmoking young male subjects, and provided some simple precautions are observed, foremost among which is the strict standardization of the recording site. These observations may have implications for the testing of endothelial function in clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Close Relation of Endothelial Function in the Human Coronary and Peripheral Circulations
Anderson, T. J., Uehata, A., Gerhard, M. D., Meredith, I. T., Knab, S., Delagrange, D., Lieberman, E. H., Ganz, P., Creager, M. A., Yeung, A. C., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00327-4 · Cited by 2,033
Joannides, R., Haefeli, W. E., Linder, L., Richard, V., Bakkali, E. H., Thuillez, C., & Lüscher, T. F. (1995) · Circulation · doi:10.1161/01.cir.91.5.1314 · Cited by 1,622
Effect of a single high-fat meal on endothelial function in healthy subjects
Vogel, R. A., Corretti, M. C., & Plotnick, G. D. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00760-6 · Cited by 798
Sorensen, K. E., Celermajer, D. S., Spiegelhalter, D. J., Georgakopoulos, D., Robinson, J., Thomas, O., & Deanfield, J. E. (1995) · Heart · doi:10.1136/hrt.74.3.247 · Cited by 694
Microvascular and macrovascular reactivity is reduced in subjects at risk for type 2 diabetes.
Caballero, A. E., Arora, S., Saouaf, R., Lim, S. C., Smakowski, P., Park, J. Y., King, G. L., LoGerfo, F. W., Horton, E. S., & Veves, A. (1999) · Diabetes · doi:10.2337/diabetes.48.9.1856 · Cited by 648
Hashimoto, M., Akishita, M., Eto, M., Ishikawa, M., Kozaki, K., Toba, K., Sagara, Y., Taketani, Y., Orimo, H., & Ouchi, Y. (1995) · Circulation · doi:10.1161/01.cir.92.12.3431 · Cited by 573
Assessment and treatment of endothelial dysfunction in humans
Anderson, T. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00259-4 · Cited by 443
Endothelial function in health and disease: new insights into the genesis of cardiovascular disease
Quyyumi, A. A. (1998) · The American Journal of Medicine · doi:10.1016/s0002-9343(98)00209-5 · Cited by 406
Veves, A., Akbari, C. M., Primavera, J., Donaghue, V. M., Zacharoulis, D., Chrzan, J. S., DeGirolami, U., LoGerfo, F. W., & Freeman, R. (1998) · Diabetes · doi:10.2337/diabetes.47.3.457 · Cited by 349
Role of nitric oxide in reactive hyperemia in human forearm vessels.
Tagawa, T., Imaizumi, T., Endo, T., Shiramoto, M., Harasawa, Y., & Takeshita, A. (1994) · Circulation · doi:10.1161/01.cir.90.5.2285 · Cited by 280
Morris, S. J., Shore, A. C., & Tooke, J. E. (1995) · Diabetologia · doi:10.1007/bf00401767 · Cited by 270
Morris, S. J., & Shore, A. C. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021704 · Cited by 254
Prediction of sampling depth and photon pathlength in laser Doppler flowmetry
Jakobsson, A., & Nilsson, G. E. (1993) · Medical & Biological Engineering & Computing · doi:10.1007/bf02458050 · Cited by 194
Correlation of Laser Doppler Wave Patterns with Underlying Microvascular Anatomy
Braverman, I. M., Keh, A., & Goldminz, D. (1990) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12484917 · Cited by 167
Noon, J. P., Walker, B. R., Hand, M. F., & Webb, D. J. (1998) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.1998.00718.x · Cited by 147
A critical review of laser Doppler flowmetry
Obeid, A. N., Barnett, N. J., Dougherty, G., & Ward, G. (1990) · Journal of Medical Engineering & Technology · doi:10.3109/03091909009009955 · Cited by 145
Arora, S., Smakowski, P., Frykberg, R. G., Simeone, L. R., Freeman, R., LoGerfo, F. W., & Veves, A. (1998) · Diabetes Care · doi:10.2337/diacare.21.8.1339 · Cited by 136
Nitric oxide and human skin blood flow responses to acetylcholine and ultraviolet light
Warren, J. B. (1994) · The FASEB Journal · doi:10.1096/fasebj.8.2.7509761 · Cited by 131
The cutaneous vascular axon reflex in humans characterized by laser Doppler perfusion imaging.
Wårdell, K., Naver, H. K., Nilsson, G. E., & Wallin, B. G. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019466 · Cited by 113
Veves, A., Saouaf, R., Donaghue, V. M., Mullooly, C. A., Kistler, J. A., Giurini, J. M., Horton, E. S., & Fielding, R. A. (1997) · Diabetes · doi:10.2337/diab.46.11.1846 · Cited by 96
Lekakis, J., Papamichael, C., Anastasiou, H., Alevizaki, M., Desses, N., Souvatzoglou, A., Stamatelopoulos, S., & Koutras, D. A. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00015-1 · Cited by 74
Andreassen, A. K., Kvernebo, K., Jørgensen, B., Simonsen, S., KJEKSHUS, J. K., & Gullestad, L. L. (1998) · American Heart Journal · doi:10.1053/hj.1998.v136.89731 · Cited by 73
Endothelium‐dependent vasodilation of the skin microcirculation in heart transplant recipients
Andreassen, A. K., Gullestad, L. L., Holm, T., Simonsen, S., & Kvernebo, K. (1998) · Clinical Transplantation · doi:10.1111/j.1399-0012.1998.tb00977.x · Cited by 45
Kowala, M. C., Valentine, M. T., Recce, R., Beyer, S. M., Goller, N. L., Durham, S. K., & Åberg, G. (1998) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-199807000-00005 · Cited by 39
Cited by
Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging
Briers, J. D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/201 · Cited by 686
Methodological issues in the assessment of skin microvascular endothelial function in humans
Cracowski, J.-L., Minson, C. T., Salvat-Melis, M., & Halliwill, J. R. (2006) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2006.07.008 · Cited by 462
Doupis, J., Lyons, T. E., Wu, S., Gnardellis, C., Dinh, T., & Veves, A. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-2385 · Cited by 266
Microvascular imaging: techniques and opportunities for clinical physiological measurements
Allen, J., & Howell, K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r91 · Cited by 208
“Choice of measurement site and measurement reproducibility are very important considerations (Kubli et al 2000), with a coefficient of variation typically of 17% found for acetylcholine iontophoresis with LDPI (Newton et al 2001b).”
BackgroundLinden, E., Cai, W., He, J. C., Xue, C., Li, Z., Winston, J., Vlassara, H., & Uribarri, J. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04291007 · Cited by 179
“, Stockholm, Sweden) (25,36,37) performed in the morning with participants fasting and resting in a comfortable chair.”
Background
Metadata
- Authors
- Kubli, S., Waeber, B., Dalle–Ave, A., & Feihl, F.
- Venue
- Journal of Cardiovascular Pharmacology
- Published
- 2000-11
- Volume
- 36
- Issue
- 5
- Pages
- 640-648
- ISSN
- 0160-2446 (ISSN-L)
- OpenAlex
- W1991590982
- Cited by
- 181
- References
- 24
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.