CoChat

New Instrument That Uses Near-Infrared Spectroscopy for the Monitoring of Human Muscle Oxygenation

Muellner, Thomas, Nikolic, Ajsa, Schramm, Wolfgang, Vecsei, Vilmos · 1999 · The Journal of Trauma: Injury, Infection, and Critical Care

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Background Early detection of vascular impairments after free tissue transfers are essential to prevent flap failure. Near-infrared spectroscopy showed good promise to monitor flaps at deep levels successfully without being invasive. The purpose of this study was to test whether the INVOS 3100 cerebral oxymeter is capable of detecting circulatory impairments. Methods In 10 healthy adults, near-infrared spectroscopy was used to measure regional saturation values during tourniquet ischemia and venous outflow restriction, in two test cycles. The probe, containing an infrared-light-emitting source and two infrared-light sensors, was placed below the elbow above the brachioradialis muscle. Statistical comparison of the data was performed using the Friedman test and the Wilcoxon-Wilcox test. Results Venous and arterial occlusions were characterized by an instantaneous fall of the regional saturation. Arterial occlusion showed a mean decrease of the saturation values down to 28+/-9%, whereas venous occlusion showed a mean fall of saturation values down to 51+/-12%. These falls were significant after 3 minutes of occlusion compared with baseline values (74+/-6%). The differences between arterial and venous occlusions were statistically significant. Conclusion This study, designed to test less-expensive equipment, was able to measure absolute values, and was not prone to interference caused by probe movement, providing information on the oxygenation profile accurately and noninvasivel…

Overview

Integrity signals

Registry

Crossref · 10.1097/00005373-199906000-00021

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 36

Metadata

Authors
Muellner, T., Nikolic, A., Schramm, W., & Vecsei, V.
Venue
The Journal of Trauma: Injury, Infection, and Critical Care
Published
1999-06
Volume
46
Issue
6
Pages
1082-1084
ISSN
1079-6061
OpenAlex
W1972316677
Cited by
34
References
13
Citations by year
2025: 2 · 2022: 1 · 2019: 1 · 2018: 1 · 2017: 2 · 2014: 1 · 2012: 2
FWCI
0.96
Type
journal article
Language
en
Open access
closed
Locations
PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
near-infrared spectroscopy, muscle oxygenation, flap monitoring, free flap, flap failure, tourniquet ischemia, arterial occlusion, venous occlusion, non-invasive monitoring
MeSH terms
Adult, Female, Humans, Male, Muscles, Oximetry, Oxygen, Vascular Diseases, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.