The DOI matches its Crossref record.
Image‐Guided Endoscopic Surgery: Results of Accuracy and Performance in a Multicenter Clinical Study Using an Electromagnetic Tracking System
Abstract
Image‐guided surgery has recently been described in the literature as a useful technology for improved functional endoscopic sinus surgery localization. Image‐guided surgery yields accurate knowledge of the surgical field boundaries, allowing safer and more thorough sinus surgery. We have previously reviewed our initial experience with The InstaTrak System. This article presents a multicenter clinical study (n=55) that assesses the system's capability for localizing structures in critical surgical sites. The purpose of this paper is to present quantitative data on accuracy and performance. We describe several new advances including an automated registration technique that eliminates the redundant computed tomography scan, compensation for head movement, and the ability to use interchangeable instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International consensus statement on allergy and rhinology: rhinosinusitis 2021
Orlandi, R. R., Kingdom, T. T., Smith, T. L., Bleier, B., DeConde, A., Luong, A. U., Poetker, D. M., Soler, Z., Welch, K. C., Wise, S. K., et al. (2021) · International Forum of Allergy & Rhinology · doi:10.1002/alr.22741 · Cited by 959
International Consensus Statement on Allergy and Rhinology: Rhinosinusitis
Orlandi, R. R., Kingdom, T. T., Hwang, P. H., Smith, T. L., Alt, J. A., Baroody, F. M., Batra, P. S., Bernal‐Sprekelsen, M., Bhattacharyya, N., Chandra, R. K., et al. (2016) · International Forum of Allergy & Rhinology · doi:10.1002/alr.21695 · Cited by 892
Electromagnetic Tracking in Medicine—A Review of Technology, Validation, and Applications
Franz, A. M., Haidegger, T., Birkfellner, W., Cleary, K., Peters, T. M., & Maier-Hein, L. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2321777 · Cited by 504
Shuhaiber, J. H. (2004) · Archives of Surgery · doi:10.1001/archsurg.139.2.170 · Cited by 321
Vision-based and marker-less surgical tool detection and tracking: a review of the literature
Bouget, D., Allan, M., Stoyanov, D., & Jannin, P. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.09.003 · Cited by 277
Metadata
- Authors
- Fried, M. P., Kleefield, J., Gopal, H., Reardon, E., Ho, B. T., & Kuhn, F. A.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 1997-05
- Volume
- 107
- Issue
- 5
- Pages
- 594-601
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2017184328
- Cited by
- 239
- References
- 0
- FWCI
- 24.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Image‐Guided Endoscopic Surgery: Results of Accuracy and Performance in a Multicenter Clinical Study Using an Electromagnetic Tracking System. https://app.cochat.ai/papers/10.1097/00005537-199705000-00008
- The paper
- Fried, M. P., Kleefield, J., Gopal, H., Reardon, E., Ho, B. T., & Kuhn, F. A. (1997). Image‐Guided Endoscopic Surgery: Results of Accuracy and Performance in a Multicenter Clinical Study Using an Electromagnetic Tracking System. The Laryngoscope. https://doi.org/10.1097/00005537-199705000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.