The DOI matches its Crossref record.
Engineering Autogenous Cartilage in the Shape of a Helix Using an Injectable Hydrogel Scaffold
Open accessAbstract
Objective Previous successful efforts to tissue engineer cartilage for an auricle have used an immunocompromised nude mouse xenograft model. Subsequent efforts in an immunocompetent autogenous animal model have been less successful because of an inflammatory response directed against the foreign scaffold polymer used to provide an auricular shape. We studied an alternative polymer material and surgical technique to engineer autogenous cartilage in the shape of a human ear helix using injectable hydrogel scaffolding, Pluronic F‐127 (polyethylene oxide and polypropylene oxide). Subject Yorkshire swine. Material and Methods Fresh autogenous chondrocytes were suspended in a biodegradable, biocompatible co‐polymer hydrogel, Pluronic F‐127, at a concentration of 3 × 10 7 cells/mL. To support the contour of the implant, a skin fold channel in the shape of the helix of a human ear was created in the skin in three sites on the ventral surface of the animal. The cell‐hydrogel suspension was injected through the skin fold channel. For controls, injections were made into identical channels using either cells alone or the Pluronic F‐127 without cells. After 10 weeks, the specimens were excised and examined both grossly and histologically. Results Grossly, all implants retained a helical‐like shape. Excised specimens possessed flexible characteristics consistent with elastic cartilage. The specimens could be folded and twisted and on release of mechanical pressure would instantly return to the original shape. Histological evaluation of the implants using H&E, Safranin O, trichrome blue, and Verhoeff's stains demonstrated findings consistent with mature elastic cartilage. Control injection of hydrogel alone demonstrated no evidence of cartilage formation and control injection of chondrocytes alone showed evidence only of disassociated elastic cartilage. Conclusion Injection of autologous porcine auricular chondrocytes suspended in a biodegradable, biocompatible hydrogel of Pluronic F‐127 resulted in the formation of cartilage tissue in the approximate size and shape of a human ear helix. This preliminary method extends the concept of auricular tissue engineering from an immunocompromised xenograft animal model to an immunocompetent autologous animal model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lee, K., Silva, E. A., & Mooney, D. J. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0223 · Cited by 1,386
A Review of Poloxamer 407 Pharmaceutical and Pharmacological Characteristics
Dumortier, G., Grossiord, J. L., Agnely, F., & Chaumeil, J. C. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9104-4 · Cited by 1,261
Chiappetta, D. A., & Sosnik, A. (2007) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.03.022 · Cited by 567
Scaffold: A Novel Carrier for Cell and Drug Delivery
Garg, T., Singh, O., Arora, S., & Murthy, R. S. R. (2012) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v29.i1.10 · Cited by 549
Hydrogels for the Repair of Articular Cartilage Defects
Spiller, K. L., Maher, S. A., & Lowman, A. M. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0077 · Cited by 470
Metadata
- Authors
- Saim, A. B., Cao, Y., Weng, Y., Chang, C., Vacanti, M. A., Vacanti, C. A., & Eavey, R. D.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2000-10
- Volume
- 110
- Issue
- 10
- Pages
- 1694-1697
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2045452294
- Cited by
- 166
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Engineering Autogenous Cartilage in the Shape of a Helix Using an Injectable Hydrogel Scaffold. https://app.cochat.ai/papers/10.1097/00005537-200010000-00023
- The paper
- Saim, A. B., Cao, Y., Weng, Y., Chang, C., Vacanti, M. A., Vacanti, C. A., & Eavey, R. D. (2000). Engineering Autogenous Cartilage in the Shape of a Helix Using an Injectable Hydrogel Scaffold. The Laryngoscope. https://doi.org/10.1097/00005537-200010000-00023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.