Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record.

Engineering Autogenous Cartilage in the Shape of a Helix Using an Injectable Hydrogel Scaffold

Open access
Saim, Aminuddin B., Cao, Yilin, Weng, Yulai, Chang, Chia‐Ning, Vacanti, Martin A., Vacanti, Charles A., Eavey, Roland D. · 2000 · The Laryngoscope

Abstract

Objective Previous successful efforts to tissue engineer cartilage for an auricle have used an immunocompromised nude mouse xenograft model. Subsequent efforts in an immunocompetent autogenous animal model have been less successful because of an inflammatory response directed against the foreign scaffold polymer used to provide an auricular shape. We studied an alternative polymer material and surgical technique to engineer autogenous cartilage in the shape of a human ear helix using injectable hydrogel scaffolding, Pluronic F‐127 (polyethylene oxide and polypropylene oxide). Subject Yorkshire swine. Material and Methods Fresh autogenous chondrocytes were suspended in a biodegradable, biocompatible co‐polymer hydrogel, Pluronic F‐127, at a concentration of 3 × 10 7 cells/mL. To support the contour of the implant, a skin fold channel in the shape of the helix of a human ear was created in the skin in three sites on the ventral surface of the animal. The cell‐hydrogel suspension was injected through the skin fold channel. For controls, injections were made into identical channels using either cells alone or the Pluronic F‐127 without cells. After 10 weeks, the specimens were excised and examined both grossly and histologically. Results Grossly, all implants retained a helical‐like shape. Excised specimens possessed flexible characteristics consistent with elastic cartilage. The specimens could be folded and twisted and on release of mechanical pressure would instantly return to the original shape. Histological evaluation of the implants using H&E, Safranin O, trichrome blue, and Verhoeff's stains demonstrated findings consistent with mature elastic cartilage. Control injection of hydrogel alone demonstrated no evidence of cartilage formation and control injection of chondrocytes alone showed evidence only of disassociated elastic cartilage. Conclusion Injection of autologous porcine auricular chondrocytes suspended in a biodegradable, biocompatible hydrogel of Pluronic F‐127 resulted in the formation of cartilage tissue in the approximate size and shape of a human ear helix. This preliminary method extends the concept of auricular tissue engineering from an immunocompromised xenograft animal model to an immunocompetent autologous animal model.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005537-200010000-00023

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Saim, A. B., Cao, Y., Weng, Y., Chang, C., Vacanti, M. A., Vacanti, C. A., & Eavey, R. D.
Venue
The Laryngoscope
Publisher
Wiley
Published
2000-10
Volume
110
Issue
10
Pages
1694-1697
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W2045452294
Cited by
166
References
0
FWCI
2.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Engineering Autogenous Cartilage in the Shape of a Helix Using an Injectable Hydrogel Scaffold. https://app.cochat.ai/papers/10.1097/00005537-200010000-00023
The paper
Saim, A. B., Cao, Y., Weng, Y., Chang, C., Vacanti, M. A., Vacanti, C. A., & Eavey, R. D. (2000). Engineering Autogenous Cartilage in the Shape of a Helix Using an Injectable Hydrogel Scaffold. The Laryngoscope. https://doi.org/10.1097/00005537-200010000-00023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.