Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 214

The DOI matches its Crossref record.

The Accuracy of Computed Tomography in the Diagnosis of Chronic Rhinosinusitis

Bhattacharyya, Neil, Fried, Marvin P. · 2003 · The Laryngoscope

Abstract

Objective To determine the sensitivity, specificity, and diagnostic accuracy of paranasal sinus computed tomography (CT) in the diagnosis of chronic rhinosinusitis (CRS). Study Design Prospective dual cohort study. Methods One hundred seventy‐one consecutive patients undergoing endoscopic sinus surgery for CRS were evaluated with CT and staged according to the Lund system. Histopathological findings from sinus specimens were reviewed and graded. A second contemporaneous control group of 130 patients undergoing CT of the sinus regions for other reasons but without a diagnosis of CRS was also staged. Sensitivity, specificity, and the receiver–operator characteristic were determined for the sinus CT in the diagnosis of CRS. Positive and negative predictive values were also computed. Results In the disease‐positive group of patients with CRS, the mean Lund score was 9.8 (95% confidence interval, 9.0–10.6). The mean inflammatory grade on histopathological study was 2.3 (range, 0–4). For the control group (without disease), the mean Lund score was 4.3 (95% confidence interval, 3.5–5.0). The AUC for the receiver–operator characteristic was 0.802 (P <.001). Selecting a Lund score cut‐off value of greater than 2 as abnormal, the sinus CT exhibited sensitivity and specificity of 94% and 41%, respectively. Increasing the cut‐off value to 4 changed the sensitivity and specificity to 85% and 59%, respectively. Conclusions The paranasal sinus CT scan exhibits good sensitivity and above‐average specificity for the diagnosis of CRS. When added to the history and physical findings, CT may add to the diagnostic accuracy of CRS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005537-200301000-00023

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 214

Metadata

Authors
Bhattacharyya, N., & Fried, M. P.
Venue
The Laryngoscope
Publisher
Wiley
Published
2003-01
Volume
113
Issue
1
Pages
125-129
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W2001598351
Cited by
214
References
0
FWCI
11.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Accuracy of Computed Tomography in the Diagnosis of Chronic Rhinosinusitis. https://app.cochat.ai/papers/10.1097/00005537-200301000-00023
The paper
Bhattacharyya, N., & Fried, M. P. (2003). The Accuracy of Computed Tomography in the Diagnosis of Chronic Rhinosinusitis. The Laryngoscope. https://doi.org/10.1097/00005537-200301000-00023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.