CoChat

The validity of regulating blood lactate concentration during running by ratings of perceived exertion

STOUDEMIRE, NANCY M., WIDEMAN, LAURIE, PASS, KIMBERLY A., McGINNES, CHRISTINA L., GAESSER, GLENN A., WELTMAN, ARTHUR · 1996 · Medicine & Science in Sports & Exercise
Cited by 98

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

We examined whether ratings of perceived exertion (RPE) observed during an incremental (response) protocol could be used to produce target blood [HLa] of 2.5 mM and 4.0 mM during a 30-min treadmill run at a constant RPE. RPE (15.3, 17.6, 19.1), oxygen uptake (VO2) (3.31, 3.96, 4.00 l.min-1), velocity (V) (198, 218, 223 m.min-1), and heart rate (HR) (179, 185, 190 bpm) at blood [HLa] of 2.5 mM and 4.0 mM, and peak were determined for nine subjects (5 males, 4 females) during incremental exercise. Subjects then completed two 30-min runs at the RPE corresponding to blood [HLa] of 2.5 mM (RPE 2.5 mM) and 4.0 mM (RPE 4.0 mM) measured during the incremental protocol. For both 30-min runs, VO2 was not different from VO2 corresponding to either 2.5 or 4.0 mM blood [HLa] during the incremental test. During the 30-min run at RPE 2.5 mM: (a) only during minutes 25-30 was the blood [HLa] significantly different than 2.5 mM (3.2 +/- 0.6 mM, P < 0.05), (b) for the first 20 min HR was significantly lower than the HR at 2.5 mM during the incremental protocol, and (c) V did not differ from V at 2.5 mM during the incremental protocol. During the 30-min run at RPE 4.0 mM: (a) blood [HLa] was not significantly different from 4.0 mM, (b) HR at every time point was significantly lower than HR 4.0 mM during the incremental protocol, and (c) V was decreased over time by an average of 24.6 m.min-1 (P < 0.05). Because RPE from the response protocol was able to produce a blood [HLa] close to the criterion value during each 30-min run, we conclude that RPE is a valid tool for prescribing exercise intensities corresponding to blood [HLa] of 2.5 mM and 4.0 mM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199604000-00014

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 98

Metadata

Authors
STOUDEMIRE, N. M., WIDEMAN, L., PASS, K. A., McGINNES, C. L., GAESSER, G. A., & WELTMAN, A.
Venue
Medicine & Science in Sports & Exercise
Published
1996-04
Volume
28
Issue
4
Pages
490-495
ISSN
0195-9131 (ISSN-L)
OpenAlex
W1988061845
Cited by
98
References
4
FWCI
4.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The validity of regulating blood lactate concentration during running by ratings of perceived exertion. https://app.cochat.ai/papers/10.1097/00005768-199604000-00014
The paper
STOUDEMIRE, N. M., WIDEMAN, L., PASS, K. A., McGINNES, C. L., GAESSER, G. A., & WELTMAN, A. (1996). The validity of regulating blood lactate concentration during running by ratings of perceived exertion. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199604000-00014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.