Clinical aspects of the control of plasma volume at microgravity and during return to one gravity
Open accessThe DOI matches its Crossref record.
Abstract
Plasma volume is reduced by 10-20% within 24-48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced maximal oxygen uptake (VO2max) after return to one gravity (1G). Since there is no evidence to suggest that plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual space flight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a "resetting" to a lower operating point, which acts to limit plasma volume expansion during attempts to increase fluid intake. In ground based and space flight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline IG operating point. Fluid-loading and lower body negative pressure (LBNP) have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other hand, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective counter measures for the control of plasma volume in microgravity and during return to IG will depend upon testing that can be conducted under standardized controlled baseline conditions during both ground-based and space flight investigations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
From space to Earth: Advances in human physiology from 20 years of bed rest studies (1986–2006)
Pavy-Le Traon, A., Heer, M., Narici, M. V., Rittweger, J., & Vernikos, J. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0474-z · Cited by 658
SAWKA, M. N., CONVERTINO, V. A., EICHNER, E. R., SCHNIEDER, S. M., & YOUNG, A. J. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200002000-00012 · Cited by 447
Self-citationChronic Orthostatic Intolerance: A Disorder With Discordant Cardiac and Vascular Sympathetic Control
Furlan, R., Jacob, G., Snell, M., Robertson, D., Porta, A., Harris, P., & Mosqueda-Garcia, R. (1998) · Circulation · doi:10.1161/01.cir.98.20.2154 · Cited by 229
Nutrition and Bone Health in Space
Smith, S. M., Heer, M., & Zwart, S. R. (2015) · Nutrition and Bone Health · doi:10.1007/978-1-4939-2001-3_41 · Cited by 14
Metadata
- Authors
- CONVERTINO, V. A.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1996-10
- Volume
- 28
- Issue
- 10
- Pages
- 45-52
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1982665257
- Cited by
- 91
- References
- 0
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical aspects of the control of plasma volume at microgravity and during return to one gravity. https://app.cochat.ai/papers/10.1097/00005768-199610000-00033
- The paper
- CONVERTINO, V. A. (1996). Clinical aspects of the control of plasma volume at microgravity and during return to one gravity. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199610000-00033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.