This review summarizes research dealing with the validity of commonly used methods for measuring systemic blood pressure during exercise. Arterial blood pressures measured from within peripheral arteries exaggerate systolic blood pressures because of wave form reflection but provide representative mean and diastolic pressures of the central arterial circulation. Manual and automated sphygmomanometry are the best noninvasive indirect methods of blood pressure measurement to estimate ascending aorta systolic pressures; however, both methods significantly underestimate diastolic pressures at rest and during exercise. The error in diastolic pressure measurement increases with increasing exercise intensity. The accuracy of many indirect noninvasive devices for blood pressure measurement at rest and during exercise can be questioned because of the use of unsuitable criterion methods. Ascending aorta pressures should ideally be used as a gold standard or criterion method for blood pressure measurement during exercise and instrument/method validation. However, given the constraints of varied criterion standards and current recommendations for blood pressure measurement, the following units were found to be acceptable devices for measuring systolic blood pressure during exercise: Accutracker II, A&D TM 2421, Colin 630 (auscultation), Critikon 1165, and possibly the Paramed 9350.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199701000-00022

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 51

Metadata

Authors
GRIFFIN, S. E., ROBERGS, R. A., & HEYWARD, V. H.
Venue
Medicine & Science in Sports & Exercise
Published
1997-01
Volume
29
Issue
1
Pages
149-159
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2029507488
Cited by
51
References
3
FWCI
4.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blood pressure measurement during exercise: a review. https://app.cochat.ai/papers/10.1097/00005768-199701000-00022
The paper
GRIFFIN, S. E., ROBERGS, R. A., & HEYWARD, V. H. (1997). Blood pressure measurement during exercise: a review. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199701000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.