Upper limit for intestinal absorption of a dilute glucose solution in men at rest
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We studied gastric and intestinal function by gastric intubation/intestinal perfusion in six healthy male volunteers to evaluate optimal use of a 6% glucose-electrolyte (GES) solution. Gastric volume, residual volume, emptying rate, and secretion were measured for an initial 763 +/- 19 ml gastric load of GES and at the beginning and end of four additional gastric loads (2.2 ml.kg-1; approximately 180 ml) given at 10-min intervals. The relatively high gastric (713 +/- 58 ml) and residual (507 +/- 26 ml) volumes maintained a high gastric emptying rate (19.5 +/- 1.4 ml.min-1). Composition of the GES emptied into the duodenum was also measured in this first experiment. In a second experiment, this modified solution was infused (triple lumen tube) into the duodenum at a rate equal to gastric emptying rate, or at 38 or 77% greater rates. Absorption of water (11.3-12.9 ml.h-1.cm-1) and glucose 4.3-5.6 mmol.h-1.cm-1) were similar at all perfusion rates during the second experiment. We conclude that duodenojejunal segmental absorption rates of water and glucose produced by a rapid, sustained gastric emptying rate cannot be increased by delivering a greater load of glucose and water by intestinal perfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of dehydration on gastric emptying and gastrointestinal distress while running
REHRER, N. J., BECKERS, E. J., BROUNS, F., HOOR, F. T., & SARIS, W. H. M. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199012000-00010 · Cited by 117
Fluid replacement during prolonged exercise: effects of water, saline, or no fluid
BARR, S. I., COSTILL, D. L., & FINK, W. J. (1991) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199107000-00007 · Cited by 67
Cited by
Physical Activity/Exercise and Type 2 Diabetes
Sigal, R. J., Kenny, G. P., Wasserman, D. H., & Castaneda-Sceppa, C. (2004) · Diabetes Care · doi:10.2337/diacare.27.10.2518 · Cited by 763
Carbohydrate intake during exercise and performance
Jeukendrup, A. E. (2004) · Nutrition · doi:10.1016/j.nut.2004.04.017 · Cited by 490
Determinants of Post-Exercise Glycogen Synthesis During Short-Term Recovery
Jentjens, R., & Jeukendrup, A. E. (2003) · Sports Medicine · doi:10.2165/00007256-200333020-00004 · Cited by 382
Oxidation of combined ingestion of glucose and fructose during exercise
Jentjens, R. L. P. G., Moseley, L., Waring, R. H., Harding, L. K., & Jeukendrup, A. E. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00974.2003 · Cited by 310
Jeukendrup, A. E., & Jentjens, R. (2000) · Sports Medicine · doi:10.2165/00007256-200029060-00004 · Cited by 279
“Studies using a triple lumen technique have measured duodenojejunal glucose absorption and estimated whole body intestinal absorption rates of a 6% glucose-electrolyte solution.[72] It was estimated that the maximal absorption rate of the intestine ranged from 1.”
MethodResult
Metadata
- Authors
- DUCHMAN, S. M., RYAN, A. J., SCHEDL, H. P., SUMMERS, R. W., BLEILER, T. L., & GISOLFI, C. V.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1997-04
- Volume
- 29
- Issue
- 4
- Pages
- 482-488
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2042436836
- Cited by
- 59
- References
- 2
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Upper limit for intestinal absorption of a dilute glucose solution in men at rest. https://app.cochat.ai/papers/10.1097/00005768-199704000-00009
- The paper
- DUCHMAN, S. M., RYAN, A. J., SCHEDL, H. P., SUMMERS, R. W., BLEILER, T. L., & GISOLFI, C. V. (1997). Upper limit for intestinal absorption of a dilute glucose solution in men at rest. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199704000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.