CALIBRATION OF THE COMPUTER SCIENCE AND APPLICATIONS, INC. (CSA) ACCELEROMETER 256
The DOI matches its Crossref record.
Abstract
Monitoring physical activity with electronic devices that use non-volatile memory is an attractive technology as it allows the user to examine patterns in physical activity as well as total activity. A new device that may be used for such purposes is the CSA accelerometer (model #7164). The device is small(5 × 5 × 1.5 cm, 70gm) which makes it particularly useful for evaluating activity in children. The aim of this study was to examine the relationship between measured METS and the 7164 accelerometer counts/min for children (age range = 6-17 yrs.). Eighty subjects (41F, 39M) completed 3, 5min treadmill conditions (2 walking and 1 jogging). CSA counts and respiratory gas exchange measures were monitored min-by-min with average of min 4 and 5 used for analysis. 50 subjects (23F, 27M) were randomly selected as the development group and 30 subjects (18F, 12M) served as the validation group. Regression analysis was used to select the significant predictors of METS: METS = 5.6832+ 0.00093(cts/min) - 0.2613(age in yrs) (R2 = 0.83). Cross-validation results (n=30) revealed no significant difference between actual and predicted METS. Pearson r = 0.86 between actual and predicted METS (SEE = ± 1.29 METS). In conclusion, these results indicate that accelerometer counts can be used to estimate different intensities of physical activity in children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Age and gender differences in objectively measured physical activity in youth
TROST, S. G., PATE, R. R., SALLIS, J. F., FREEDSON, P. S., TAYLOR, W. C., DOWDA, M., & SIRARD, J. (2002) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200202000-00025 · Cited by 1,451
Self-citationThe evolving definition of “sedentary.”
Pate, R. R., O'Neill, J. R., & Lobelo, F. (2008) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181877d1a · Cited by 1,280
Self-citationUsing objective physical activity measures with youth: How many days of monitoring are needed?
TROST, S. G., PATE, R. R., FREEDSON, P. S., SALLIS, J. F., & TAYLOR, W. C. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200002000-00025 · Cited by 1,136
Self-citationCalibration of Accelerometer Output for Children
FREEDSON, P., POBER, D., & JANZ, K. F. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185658.28284.ba · Cited by 1,104
Self-citationUsing Accelerometers in Youth Physical Activity Studies: A Review of Methods
Cain, K. L., Sallis, J. F., Conway, T. L., Van Dyck, D., & Calhoon, L. (2013) · Journal of Physical Activity and Health · doi:10.1123/jpah.10.3.437 · Cited by 713
Self-citation
Metadata
- Authors
- Freedson, P. S., Sirard, J., Debold, E., Pate, R., Dowda, M., Trost, S., & Sallis, J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1997-05
- Volume
- 29
- Issue
- Supplement
- Pages
- 45
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1967399175
- Cited by
- 153
- References
- 0
- Type
- conference abstract
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CALIBRATION OF THE COMPUTER SCIENCE AND APPLICATIONS, INC. (CSA) ACCELEROMETER 256. https://app.cochat.ai/papers/10.1097/00005768-199705001-00256
- The paper
- Freedson, P. S., Sirard, J., Debold, E., Pate, R., Dowda, M., Trost, S., & Sallis, J. (1997). CALIBRATION OF THE COMPUTER SCIENCE AND APPLICATIONS, INC. (CSA) ACCELEROMETER 256. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199705001-00256
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.