CoChat

Relationships between TriTrac-R3D vectors, heart rate, and self-report in obese children

COLEMAN, KAREN J., SAELENS, BRIAN E., WIEDRICH-SMITH, MARGO D., FINN, JEREMY D., EPSTEIN, LEONARD H. · 1997 · Medicine & Science in Sports & Exercise
Cited by 65

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The TriTrac (Professional Products, Inc., Madison, WI) triaxial accelerometer and diary self report were compared with adjusted heart rates to evaluate 3 d of leisure-time activity in 35 8- to 12-yr-old obese children. Adjusted heart rates were calculated by subtracting preexercise resting heart rates from heart rates measured in the field. TriTrac and self-reported data were converted to multiples of resting metabolic rate (METs). Correlations between accelerometer METs and adjusted heart rates (r = 0.71) were significantly higher (P < 0.001) than correlations between adjusted heart rates and self-reported METs (r = 0.36) or accelerometer and self-reported METs (r = 0.38). Self-reported METs had higher mean standard errors in estimating heart rates (13.93 +/- 6.15 beats.min-1) than did accelerometer METs (10.94 +/- 5.62 beats.min-1; P < 0.001), were significantly greater than accelerometer METs (2.50 +/- 1.48 vs 1.80 +/- 1.48; P < 0.05) and systematically overestimated accelerometer METs. The anteroposterior vector accounted for 36%, and the vector magnitude score accounted for 34% of the variance in unadjusted heart rates. The mediolateral vector and vector magnitude score accounted for 69% of the variance in self-reported METs. The vertical vector did not account for variance in either unadjusted heart rates or self-reported METs. It was concluded that the TriTrac yielded a better estimate of activity in obese children than self report. In addition, the vector magnitude composite score of the TriTrac accounted for significantly more variance in both self-reported activity and unadjusted heart rates as compared with the vertical directional vector of the TriTrac.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199711000-00022

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 65

Metadata

Authors
COLEMAN, K. J., SAELENS, B. E., WIEDRICH-SMITH, M. D., FINN, J. D., & EPSTEIN, L. H.
Venue
Medicine & Science in Sports & Exercise
Published
1997-11
Volume
29
Issue
11
Pages
1535-1542
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2057756656
Cited by
65
References
3
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relationships between TriTrac-R3D vectors, heart rate, and self-report in obese children. https://app.cochat.ai/papers/10.1097/00005768-199711000-00022
The paper
COLEMAN, K. J., SAELENS, B. E., WIEDRICH-SMITH, M. D., FINN, J. D., & EPSTEIN, L. H. (1997). Relationships between TriTrac-R3D vectors, heart rate, and self-report in obese children. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199711000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.