The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: This study examined the reliability and validity of the TriTrac-R3D triaxial accelerometer to estimate energy expenditure during various modes of exercise. METHODS: Twenty subjects (age = 21.5+/-3.4 yr; body mass index = 23.3+/-3.6 kg x m(-2)) performed five exercises (treadmill walking, treadmill running, stepping, stationary cycling, and slideboard), with each lasting 20-30 min and workload increased at 10-min intervals. To test the inter-TriTrac reliability, two TriTrac-R3D accelerometers were worn during each exercise period, and to examine validity, a simultaneous measurement of energy expenditure was made using indirect calorimetry (SensorMedics 2900 Metabolic Cart). RESULTS: Results showed a significant correlation between the two TriTrac-R3D accelerometers during all exercises. The difference in estimated energy expenditure between the two accelerometers during the walking, stepping, and slideboard exercises was less than 1 kcal x min(-1) but statistically significant (P<0.05). There was also a significant correlation between energy expenditure estimated by each of the TriTrac-R3D accelerometers and indirect calorimetry during walking, running, stepping, and slideboard exercise (P<0.05). The interaction of Method x Workload was significant (P<0.05) for each exercise, indicating that the TriTrac-R3D underestimates energy expenditure and that the magnitude of this underestimation increases as workload increases. CONCLUSIONS: Therefore, energy expenditure estimated via triaxial accelerometry does not increase with increasing workloads. These results suggest that there are limitations to using triaxial accelerometry to quantify energy expenditure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Metadata
- Authors
- JAKICIC, J. M., WINTERS, C., LAGALLY, K., HO, J., ROBERTSON, R. J., & WING, R. R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1999-05
- Volume
- 31
- Issue
- 5
- Pages
- 747-754
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1974010325
- Cited by
- 149
- References
- 1
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure. https://app.cochat.ai/papers/10.1097/00005768-199905000-00020
- The paper
- JAKICIC, J. M., WINTERS, C., LAGALLY, K., HO, J., ROBERTSON, R. J., & WING, R. R. (1999). The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199905000-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.