CoChat

Measurement of maximal oxygen uptake from two different laboratory protocols in runners and squash players

GIBSON, ALAN ST CLAIR, LAMBERT, MICHAEL I., HAWLEY, JOHN A., BROOMHEAD, SALI-ANN, NOAKES, TIMOTHY D. · 1999 · Medicine & Science in Sports & Exercise
Cited by 53

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: The aims of the study were to assess whether different test protocols used to elicit maximal oxygen uptake values (VO2max) attain similar results, whether different VO2max protocols were preferable for different athletic groups, and to assess whether the noninvasive criteria used to indicate the attainment of VO2max are achieved similarly in different VO2max testing protocols. METHODS: This study evaluated the attainment of either VO2max or peak VO2 (VO2peak) during two treadmill VO2max protocols: a progressive speed protocol (PSP) and a progressive incline protocol (PIP). Ten runners and 10 squash players were studied to assess whether achievement of VO2max criteria was either sport-specific or protocol-specific, or both. RESULTS: There were no significant differences in the VO2peak values reached in either PSP or PIP protocol (64.4 +/- 5.9 vs 66.5 +/- 6.0 mLO2 x kg(-1) x min(-1)). But HRmax (196 +/- 5 vs 189 +/- 5 beats x min(-1); PSP vs PIP; P < 0.01) and RER (1.14 +/- 0.05 vs 1.07 +/- 0.04; PSP vs PIP; P < 0.01) were significantly higher during the PSP test. Fifty percent of the subjects reached a plateau in either test, and of these subjects, 90% satisfied the three noninvasive criteria for VO2max in the PSP group, compared with 10% in the PIP group. CONCLUSIONS: The indirect criteria used to assess the attainment of VO2max may be limited, as the VO2peak values were higher in the PIP protocol compared with the PSP protocol, although not significantly different, whereas the HR and RER values were significantly lower in the PIP than PSP protocol. Furthermore, only 50% of subjects demonstrated the plateau phenomenon in oxygen uptake with either protocol. It may be concluded that the measured physiological variables coinciding with VO2peak may differ when different protocols are used to elicit VO2max.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199908000-00022

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 53

Metadata

Authors
GIBSON, A. S. C., LAMBERT, M. I., HAWLEY, J. A., BROOMHEAD, S.-A., & NOAKES, T. D.
Venue
Medicine & Science in Sports & Exercise
Published
1999-08
Volume
31
Issue
8
Pages
1226-1229
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2095238601
Cited by
53
References
4
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of maximal oxygen uptake from two different laboratory protocols in runners and squash players. https://app.cochat.ai/papers/10.1097/00005768-199908000-00022
The paper
GIBSON, A. S. C., LAMBERT, M. I., HAWLEY, J. A., BROOMHEAD, S.-A., & NOAKES, T. D. (1999). Measurement of maximal oxygen uptake from two different laboratory protocols in runners and squash players. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199908000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.