The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Force and EMG power spectrum during eccentric and concentric actions
Abstract
INTRODUCTION: This study was designed to examine the force and activation levels of elbow flexor muscles during preactivated eccentric, concentric and isometric actions. METHODS: Force, average EMG (aEMG), and the EMG power spectrum were investigated at different constant movement velocities (1 rad x s(-1), 2 rad x s(-1), 3 rad x s(-1), and 4 rad x s(-1)) at different joint angles. RESULTS: Average force at a 110 degree elbow angle was lower and aEMG was higher in concentric actions as compared with eccentric and isometric actions. At a 55 degree elbow angle, there was no difference in aEMG, or it was slightly higher in eccentric actions. MF was higher in the concentric as compared with eccentric actions at the three fastest velocities at the 110 degree elbow angle, whereas no difference was observed at the 55 degree elbow angle. In concentric action, MF was higher in 4 rad x s(-1) in comparison with 1 rads x s(-1) at 110 degree elbow angle. DISCUSSION: These results suggest that it is difficult to maintain the maximal eccentric force throughout the whole range of motion. Maximal EMG activity and frequencies of the EMG power spectrum can be at the same level or lower in eccentric actions as compared with concentric actions, depending on the joint angle and preactivation mode. The results of the EMG power spectrum do not support the concept that in maximal eccentric actions fast units are selectively activated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FUNCTIONAL SIGNIFICANCE OF CELL SIZE IN SPINAL MOTONEURONS
Henneman, E., Somjen, G., & Carpenter, D. O. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.560 · Cited by 2,294
The relation between force and velocity in human muscle
Wilkie, D. R. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004437 · Cited by 632
Cited by
Bojsen-Møller, J., Magnusson, S. P., Rasmussen, L. R., Kjaer, M., & Aagaard, P. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01305.2004 · Cited by 532
Franchi, M. V., Reeves, N. D., & Narici, M. V. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00447 · Cited by 386
Resistance training using eccentric overload induces early adaptations in skeletal muscle size
Norrbrand, L., Fluckey, J. D., Pozzo, M., & Tesch, P. A. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0583-8 · Cited by 253
Neural Adaptations with Chronic Activity Patterns in Able-Bodied Humans
Duchateau, J., & Enoka, R. M. (2002) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200211001-00004 · Cited by 109
Electromyographic activity in deadlift exercise and its variants. A systematic review
Martín-Fuentes, I., Oliva-Lozano, J. M., & Muyor, J. M. (2020) · PLOS ONE · doi:10.1371/journal.pone.0229507 · Cited by 70
Metadata
- Authors
- KOMI, P. V., LINNAMO, V., SILVENTOINEN, P., & SILLANP????, M.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2000-10
- Volume
- 32
- Issue
- 10
- Pages
- 1757-1762
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2067206473
- Cited by
- 190
- References
- 2
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Force and EMG power spectrum during eccentric and concentric actions. https://app.cochat.ai/papers/10.1097/00005768-200010000-00015
- The paper
- KOMI, P. V., LINNAMO, V., SILVENTOINEN, P., & SILLANP????, M. (2000). Force and EMG power spectrum during eccentric and concentric actions. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-200010000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.