CoChat

Is there a threshold intensity for aerobic training in cardiac patients?

SWAIN, DAVID P., FRANKLIN, BARRY A. · 2002 · Medicine & Science in Sports & Exercise

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

PURPOSE: Recent guidelines have recommended the use of a percentage of oxygen uptake reserve (VO2R) for prescribing aerobic exercise intensity for cardiac patients. Moreover, these guidelines suggest that a threshold intensity may exist, below which no improvement in peak oxygen uptake (VO2peak) occurs. The purpose, therefore, was to translate the intensity of aerobic exercise in previous training studies using cardiac patients into %VO2R units, and determine whether a threshold intensity exists. METHODS: Twenty-three studies, using 28 groups of aerobically trained cardiac patients, were identified in which VO2peak was measured before and after training by gas exchange. Intensity of exercise was variously described as a percentage of VO2peak, percentage of peak heart rate (HRpeak), percentage of heart rate reserve (HRR), or percentage of peak workload. These intensities were translated into equivalent units of %VO2R. RESULTS: Of the 28 groups of patients, three failed to show significant improvements in VO2peak. These groups exercised at intensities corresponding to 47-55% of VO2R. However, six other groups exercised at comparable intensities (i.e., 42% to 55% of VO2R) and experienced significant increases in VO2peak. Other confounding variables in these studies were similar, including the initial VO2peak of the subjects, suggesting that the failure of three groups to significantly improve aerobic capacity was due to their small sample size. CONCLUSION: No threshold intensity for aerobic training was identified in cardiac patients, with the lowest intensity studied being approximately 45% of VO2R. It is possible that intensities below this value may be an effective training stimulus, especially in extremely deconditioned subjects, but further research is needed to test that possibility and to determine whether a threshold exists.

Overview

Integrity signals

Registry

Crossref · 10.1097/00005768-200207000-00003

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 34 references

Research works printed but not linked: 6

  1. Chang, 1982, J Cardiac Rehabil, 2, 326
  2. Costill, 1974, Med Sci Sports, 6, 95
  3. Franklin, 1978, Arch Phys Med Rehabil, 59, 276
  4. Kasch, 1969, Med Sci Sports, 1, 156
  5. Keyser, 1993, Arch Phys Med Rehabil, 74, 276
  6. Pollock, 1998, Med Sci Sports Exerc, 30, 975

Cited by

See all 67

Metadata

Authors
SWAIN, D. P., & FRANKLIN, B. A.
Affiliations
Beaumont Health (US)
Venue
Medicine & Science in Sports & Exercise
Published
2002-07
Volume
34
Issue
7
Pages
1071-1075
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2110408418
Cited by
67
References
34
Citations by year
2026: 1 · 2024: 1 · 2023: 4 · 2022: 1 · 2021: 1 · 2020: 2 · 2018: 2 · 2017: 4 · 2016: 1 · 2015: 3 · 2014: 4 · 2013: 4 · 2012: 8
FWCI
0.58
Type
journal article
Language
en
Open access
closed
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
  • ODU Digital Commons (Old Dominion University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
Keywords
aerobic exercise, cardiac patients, exercise intensity, oxygen uptake reserve, threshold intensity, peak oxygen uptake, heart rate reserve, heart rate, training stimulus, cardiac rehabilitation
MeSH terms
Exercise Therapy, Heart Diseases, Heart Rate, Humans, Oxygen Consumption, Physical Fitness, Pulmonary Gas Exchange, Exercise

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Is there a threshold intensity for aerobic training in cardiac patients? https://app.cochat.ai/papers/10.1097/00005768-200207000-00003
The paper
SWAIN, D. P., & FRANKLIN, B. A. (2002). Is there a threshold intensity for aerobic training in cardiac patients? Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-200207000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.