Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 164

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Cerebral Venous Oxygen Saturation Studied with Bilateral Samples in the Internal Jugular Veins

Stocchetti, Nino, Paparella, Alessandro, Bridelli, Franca, Bacchi, Marisa, Piazza, Paolo, Zuccoli, Paolo · 1994 · Neurosurgery

Abstract

THE CURRENT LITERATURE reports many measurements (arteriovenous oxygen content difference and cerebral metabolic rate of oxygen, etc.) with samples from the internal jugular veins (IJs), obtained from either side of the neck, based on the assumption that a reliable sample of mixed venous blood can be drawn. We compared oxygen saturation in both IJs in 32 patients with head injuries to establish the similarities or discrepancies in the two veins. Both IJs were cannulated with 20-G catheters; in five patients, a fiberoptic catheter was used to obtain a continuous recording of the hemoglobin saturation. Blood samples were taken simultaneously from the two IJs and immediately processed; the total number of samples processed was 342, with an average of 5.34 paired samples from each patient. The mean and the standard deviation of the differences between the saturation of the two IJs were, respectively, 5.32 and 5.15. Fifteen patients showed differences greater than 15% in hemoglobin saturation; three more patients showed differences greater than 10% at some point during the investigation. Ultimately, only eight patients had differences of less than 5%. No relationship was found among the computed tomographic scan data and the pattern of hemoglobin saturation detected. Therefore, we were not able to identify the side more appropriate for monitoring in patients with bilateral, predominantly monolateral, cortical, or deeply located lesions. The 95% confidence limits for the percentage of patients with a difference higher than 15% were between 30 and 64%; the limits for the percentage of patients with a difference higher than 10 were between 39 and 73%; ultimately, the limits for the percentage of patients with a difference higher than 5 were between 60 and 90%. The proportion of patients with relevant discrepancies between the two IJs is higher than suspected, and the reliability of a single item of data obtained from a single IJ is questionable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-199401000-00007

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 164

Metadata

Authors
Stocchetti, N., Paparella, A., Bridelli, F., Bacchi, M., Piazza, P., & Zuccoli, P.
Venue
Neurosurgery
Published
1994-01-01
Volume
34
Issue
1
Pages
38-44
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2092548777
Cited by
164
References
2
FWCI
11.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cerebral Venous Oxygen Saturation Studied with Bilateral Samples in the Internal Jugular Veins. https://app.cochat.ai/papers/10.1097/00006123-199401000-00007
The paper
Stocchetti, N., Paparella, A., Bridelli, F., Bacchi, M., Piazza, P., & Zuccoli, P. (1994). Cerebral Venous Oxygen Saturation Studied with Bilateral Samples in the Internal Jugular Veins. Neurosurgery. https://doi.org/10.1097/00006123-199401000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.