The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Assessment of cerebral pressure autoregulation in humans - a review of measurement methods
Abstract
Assessment of cerebral autoregulation is an important adjunct to measurement of cerebral blood flow for diagnosis, monitoring or prognosis of cerebrovascular disease. The most common approach tests the effects of changes in mean arterial blood pressure on cerebral blood flow, known as pressure autoregulation. A 'gold standard' for this purpose is not available and the literature shows considerable disparity of methods and criteria. This is understandable because cerebral autoregulation is more a concept rather than a physically measurable entity. Static methods utilize steady-state values to test for changes in cerebral blood flow (or velocity) when mean arterial pressure is changed significantly. This is usually achieved with the use of drugs, shifts in blood volume or by observing spontaneous changes. The long time interval between measurements is a particular concern in many of the studies reviewed. Parallel changes in other critical variables, such as pCO2, haematocrit, brain activation and sympathetic tone, are rarely controlled for. Proposed indices of static autoregulation are based on changes in cerebrovascular resistance, on parameters of the linear regression of flow/velocity versus pressure changes, or only on the absolute changes in flow. The limitations of studies which assess patient groups rather than individual cases are highlighted. Newer methods of dynamic assessment are based on transient changes in cerebral blood flow (or velocity) induced by the deflation of thigh cuffs, Valsalva manoeuvres, tilting and induced or spontaneous oscillations in mean arterial blood pressure. Dynamic testing overcomes several limitations of static methods but it is not clear whether the two approaches are interchangeable. Classification of autoregulation performance using dynamic methods has been based on mathematical modelling, coherent averaging, transfer function analysis, crosscorrelation function or impulse response analysis. More research on reproducibility and inter-method comparisons is urgently needed, particularly involving the assessment of pressure autoregulation in individuals rather than patient groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Monitoring of autoregulation using laser Doppler flowmetry in patients with head injury
Lam, J. M. K., Hsiang, J. N. K., & Poon, W. S. (1997) · Journal of Neurosurgery · doi:10.3171/jns.1997.86.3.0438 · Cited by 150
Cited by
Regulation of cerebral blood flow in humans: physiology and clinical implications of autoregulation
Claassen, J. A. H. R., Thijssen, D. H. J., Panerai, R. B., & Faraci, F. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00022.2020 · Cited by 915
Self-citationvan Beek, A. H., Claassen, J. A., Rikkert, M. G. O., & Jansen, R. W. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.13 · Cited by 485
Continuous Time-Domain Analysis of Cerebrovascular Autoregulation Using Near-Infrared Spectroscopy
Brady, K. M., Lee, J. K., Kibler, K. K., Smielewski, P., Czosnyka, M., Easley, R. B., Koehler, R. C., & Shaffner, D. H. (2007) · Stroke · doi:10.1161/strokeaha.107.485706 · Cited by 384
Syncope, cerebral perfusion, and oxygenation
Van Lieshout, J. J., Wieling, W., Karemaker, J. M., & Secher, N. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00260.2002 · Cited by 365
The relationship between blood pressure and cognitive function
Novak, V., & Hajjar, I. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.161 · Cited by 299
Metadata
- Authors
- Panerai, R. B.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1998-08-01
- Volume
- 19
- Issue
- 3
- Pages
- 305-338
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2022121530
- Cited by
- 508
- References
- 4
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of cerebral pressure autoregulation in humans - a review of measurement methods. https://app.cochat.ai/papers/10.1088/0967-3334/19/3/001
- The paper
- Panerai, R. B. (1998). Assessment of cerebral pressure autoregulation in humans - a review of measurement methods. Physiological Measurement. https://doi.org/10.1088/0967-3334/19/3/001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.