Abstract
OBJECTIVE: To demonstrate the feasibility of transcranial high-frequency electrical stimulation with the patient under general anesthesia with propofol and alfentanil. This method may be a useful tool for intraoperative monitoring of the motor pathways during cerebral and spinal operations. METHODS: A short train from one to eight monopolar anodal electrical pulses was applied transcranially to the motor cortex with a frequency from 100 to 500 Hz in 10 patients. Myogenic motor evoked potentials (MEPs) were recorded from forearm flexor muscles, thenar, and hypothenar. Amplitude and latency of MEPs were evaluated after different stimulation parameters. This combination of anesthetic and transcranial stimulation technique allows recording of myogenic MEPs during general anesthesia, which was found not to be possible with single pulse transcranial stimulation. RESULTS: To elicit myogenic MEPs from the target muscles, stimulation had to be applied within the following parameters: minimum threshold intensity was 60 mA for forearm flexor and thenar and 80 mA for hypothenar; minimum number of pulses was two for forearm flexor muscles and thenar and three for hypothenar; minimum stimulation frequency was 200 Hz for thenar and hypothenar and 100 Hz for forearm flexor muscles. CONCLUSION: Transcranial high-frequency repetitive electrical stimulation seems to be a new method for monitoring the motor tract. With this method, it is possible to monitor the motor function without interfering with the surgical team or with the surgical treatment of infratentorial and spinal lesions. Monitoring of relaxation is necessary to compare the amplitude of MEPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Responses to rapid-rate transcranial magnetic stimulation of the human motor cortex
Pascual-Leone, A., Valls-Solé, J., Wassermann, E. M., & Hallett, M. (1994) · Brain · doi:10.1093/brain/117.4.847 · Cited by 1,457
Human motor evoked responses to paired transcranial magnetic stimuli
Valls-Solé, J., Pascual-Leone, A., Wassermann, E. M., & Hallett, M. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90048-g · Cited by 687
Inhibition of Adrenal Steroidogenesis by the Anesthetic Etomidate
Wagner, R. L., White, P. F., Kan, P. B., Rosenthal, M. H., & Feldman, D. (1984) · New England Journal of Medicine · doi:10.1056/nejm198405313102202 · Cited by 555
Modification of Cortical Stimulation for Motor Evoked Potentials under General Anesthesia
Taniguchi, M., Cedzich, C., Taniguchi, M., Cedzich, C., & Schramm, J. (1993) · Neurosurgery · doi:10.1227/00006123-199302000-00011 · Cited by 554
Self-citationINFLUENCE OF SEDATION ON MORTALITY IN CRITICALLY ILL MULTIPLE TRAUMA PATIENTS
LEDINGHAM, I. (1983) · The Lancet · doi:10.1016/s0140-6736(83)92712-5 · Cited by 492
Cedzich, C., Taniguchi, M., Schäfer, S., & Schramm, J. (1996) · Neurosurgery · doi:10.1097/00006123-199605000-00023 · Cited by 344
Self-citationBoyd, S. G., Rothwell, J. C., Cowan, J. M., Webb, P. J., Morley, T., Asselman, P., & Marsden, C. D. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.3.251 · Cited by 329
Spinal Cord Monitoring During Operative Treatment of the Spine
NASH, C. L., LORIG, R. A., SCHATZINGER, L. A., & BROWN, R. H. (1977) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197707000-00014 · Cited by 312
Considerations for safety in the use of extracranial stimulation for motor evoked potentials
Agnew, W. F., & McCreery, D. B. (1987) · Neurosurgery · doi:10.1097/00006123-198701000-00030 · Cited by 265
Cited by
Ziemann, U., Reis, J., Schwenkreis, P., Rosanova, M., Strafella, A., Badawy, R., & Müller-Dahlhaus, F. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.08.028 · Cited by 681
Ziemann, U. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.03.006 · Cited by 629
MacDonald, D. B., Skinner, S., Shils, J., & Yingling, C. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.07.025 · Cited by 568
Sala, F., Palandri, G., Basso, E., Lanteri, P., Deletis, V., Faccioli, F., & Bricolo, A. (2006) · Neurosurgery · doi:10.1227/01.neu.0000215948.97195.58 · Cited by 452
Intraoperative Motor Evoked Potential Monitoring: Overview and Update
MacDonald, D. B. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9033-0 · Cited by 348
Safety of Intraoperative Transcranial Electrical Stimulation Motor Evoked Potential Monitoring
MacDonald, D. B. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200210000-00005 · Cited by 342
Motor Evoked Potential Monitoring with Supratentorial Surgery
Neuloh, G., Pechstein, U., Cedzich, C., & Schramm, J. (2004) · Neurosurgery · doi:10.1227/01.neu.0000119326.15032.00 · Cited by 233
Self-citationMotor tract monitoring during insular glioma surgery
Neuloh, G., Pechstein, U., & Schramm, J. (2007) · Journal of Neurosurgery · doi:10.3171/jns.2007.106.4.582 · Cited by 221
Self-citationScheufler, K.-M., & Zentner, J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.96.3.0571 · Cited by 177
Szelényi, A., Kothbauer, K. F., & Deletis, V. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.008 · Cited by 175
Pajewski, T. N., Arlet, V., & Phillips, L. H. (2007) · European Spine Journal · doi:10.1007/s00586-007-0419-6 · Cited by 171
“The anesthetic gas nitrous oxide reduces SSEP cortical amplitude and increases latency when used alone or when combined with halogenated inhalational agents, opioids or propofol [47, 65, 67, 72].”
Background
Metadata
- Authors
- Pechstein, U., Ceclzich, C., Nadstawek, J., & Schramm, J.
- Venue
- Neurosurgery
- Published
- 1996-08-01
- Volume
- 39
- Issue
- 2
- Pages
- 335-344
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2052512458
- Cited by
- 246
- References
- 19
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.