Depth Electrode Implantation in the Length Axis of the Hippocampus for the Presurgical Evaluation of Medial Temporal Lobe Epilepsy: A Computed Tomography-based Stereotactic Insertion Technique and Its Accuracy
The DOI matches its Crossref record.
Abstract
OBJECTIVE: An individualized computed tomography-based stereotactic technique for the longitudinal insertion of intrahippocampal electrodes is presented and its accuracy described. METHODS: The technique makes use of one well reproducible target in the hippocampal head and of the approximate inclination of the anteroposterior length axis of the hippocampus, for which the orbital floor is taken as an auxiliary landmark. It was used in 141 patients with medically intractable complex partial seizures. In 106 patients, magnetic resonance imaging (MRI) was available for assessment of implantation accuracy. Each of the 212 electrodes was plotted on topographic drawings and its goodness of fit rated. RESULTS: Whereas hippocampal head and body were hit by 97 and 96% of the electrodes, respectively, the amygdala was hit by only 75% of the electrodes and mainly at its basal margin. For 93% of the electrodes, the inclination in a sagittal plane corresponded exactly to that of the hippocampus. The implantation morbidity amounted to 5.7%, whereas permanent neurological deficit occurred in one (0.7%) of the 141 patients. CONCLUSION: This computed tomography-based protocol proved to be reliable and hence can be considered as an adequate alternative to MRI-based stereotactic implantation if MRI is not available or if a single MRI-based stereotactic set-up is unreliable because of intolerable distortions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human memory formation is accompanied by rhinal–hippocampal coupling and decoupling
Fell, J., Klaver, P., Lehnertz, K., Grunwald, T., Schaller, C., Elger, C. E., & Fernández, G. (2001) · Nature Neuroscience · doi:10.1038/nn759 · Cited by 691
Luyken, C., Blümcke, I., Fimmers, R., Urbach, H., Elger, C. E., Wiestler, O. D., & Schramm, J. (2003) · Epilepsia · doi:10.1046/j.1528-1157.2003.56102.x · Cited by 466
Self-citationEpileptic seizures are preceded by a decrease in synchronization
Mormann, F., Kreuz, T., Andrzejak, R. G., David, P., Lehnertz, K., & Elger, C. E. (2003) · Epilepsy Research · doi:10.1016/s0920-1211(03)00002-0 · Cited by 456
Mullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Mormann, F., Fell, J., Axmacher, N., Weber, B., Lehnertz, K., Elger, C. E., & Fernández, G. (2005) · Hippocampus · doi:10.1002/hipo.20117 · Cited by 411
Metadata
- Authors
- Van Roost, D., Solymosi, L., Schramm, J., van Oosterwyck, B., & Eiger, C. E.
- Venue
- Neurosurgery
- Published
- 1998-10
- Volume
- 43
- Issue
- 4
- Pages
- 819-826
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2023081579
- Cited by
- 114
- References
- 0
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Depth Electrode Implantation in the Length Axis of the Hippocampus for the Presurgical Evaluation of Medial Temporal Lobe Epilepsy: A Computed Tomography-based Stereotactic Insertion Technique and Its Accuracy. https://app.cochat.ai/papers/10.1097/00006123-199810000-00058
- The paper
- Van Roost, D., Solymosi, L., Schramm, J., van Oosterwyck, B., & Eiger, C. E. (1998). Depth Electrode Implantation in the Length Axis of the Hippocampus for the Presurgical Evaluation of Medial Temporal Lobe Epilepsy: A Computed Tomography-based Stereotactic Insertion Technique and Its Accuracy. Neurosurgery. https://doi.org/10.1097/00006123-199810000-00058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.