Depth Electrode Implantation in the Length Axis of the Hippocampus for the Presurgical Evaluation of Medial Temporal Lobe Epilepsy: A Computed Tomography-based Stereotactic Insertion Technique and Its Accuracy
The DOI matches its Crossref record.
Abstract
OBJECTIVE: An individualized computed tomography-based stereotactic technique for the longitudinal insertion of intrahippocampal electrodes is presented and its accuracy described. METHODS: The technique makes use of one well reproducible target in the hippocampal head and of the approximate inclination of the anteroposterior length axis of the hippocampus, for which the orbital floor is taken as an auxiliary landmark. It was used in 141 patients with medically intractable complex partial seizures. In 106 patients, magnetic resonance imaging (MRI) was available for assessment of implantation accuracy. Each of the 212 electrodes was plotted on topographic drawings and its goodness of fit rated. RESULTS: Whereas hippocampal head and body were hit by 97 and 96% of the electrodes, respectively, the amygdala was hit by only 75% of the electrodes and mainly at its basal margin. For 93% of the electrodes, the inclination in a sagittal plane corresponded exactly to that of the hippocampus. The implantation morbidity amounted to 5.7%, whereas permanent neurological deficit occurred in one (0.7%) of the 141 patients. CONCLUSION: This computed tomography-based protocol proved to be reliable and hence can be considered as an adequate alternative to MRI-based stereotactic implantation if MRI is not available or if a single MRI-based stereotactic set-up is unreliable because of intolerable distortions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human memory formation is accompanied by rhinal–hippocampal coupling and decoupling
Fell, J., Klaver, P., Lehnertz, K., Grunwald, T., Schaller, C., Elger, C. E., & Fernández, G. (2001) · Nature Neuroscience · doi:10.1038/nn759 · Cited by 691
Luyken, C., Blümcke, I., Fimmers, R., Urbach, H., Elger, C. E., Wiestler, O. D., & Schramm, J. (2003) · Epilepsia · doi:10.1046/j.1528-1157.2003.56102.x · Cited by 466
Self-citationEpileptic seizures are preceded by a decrease in synchronization
Mormann, F., Kreuz, T., Andrzejak, R. G., David, P., Lehnertz, K., & Elger, C. E. (2003) · Epilepsy Research · doi:10.1016/s0920-1211(03)00002-0 · Cited by 456
Mullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Mormann, F., Fell, J., Axmacher, N., Weber, B., Lehnertz, K., Elger, C. E., & Fernández, G. (2005) · Hippocampus · doi:10.1002/hipo.20117 · Cited by 411
Ripples in the medial temporal lobe are relevant for human memory consolidation
Axmacher, N., Elger, C. E., & Fell, J. (2008) · Brain · doi:10.1093/brain/awn103 · Cited by 372
“All patients had bilateral medial temporal depth electrodes that were inserted for diagnostic purposes using a computed tomography-based stereotactic insertion technique (Van Roost et al., 1998).”
MethodReal-Time Tracking of Memory Formation in the Human Rhinal Cortex and Hippocampus
Fernández, G., Effern, A., Grunwald, T., Pezer, N., Lehnertz, K., Dümpelmann, M., Roost, D. V., & Elger, C. E. (1999) · Science · doi:10.1126/science.285.5433.1582 · Cited by 345
Sustained Neural Activity Patterns during Working Memory in the Human Medial Temporal Lobe
Axmacher, N., Mormann, F., Fernández, G., Cohen, M. X., Elger, C. E., & Fell, J. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0962-07.2007 · Cited by 261
Fell, J., Klaver, P., Elfadil, H., Schaller, C., Elger, C. E., & Fernández, G. (2003) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2003.02522.x · Cited by 215
Axmacher, N., Schmitz, D. P., Wagner, T., Elger, C. E., & Fell, J. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.1778-08.2008 · Cited by 204
“Multicontact depth electrodes and temporal basal strips were inserted for diagnostic purposes using a computed tomography-based stereotactic insertion technique (Van Roost et al., 1998).”
MethodFell, J., Ludowig, E., Staresina, B. P., Wagner, T., Kranz, T., Elger, C. E., & Axmacher, N. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.3668-10.2011 · Cited by 203
“To reduce potential contamination by epileptogenic processes, only EEG recordings from the MTL contralateral to the zone of seizure origin were analyzed (Puce et al., 1989; Grunwald et al., 1995).”
MethodMolecular neuropathology of human mesial temporal lobe epilepsy
Blümcke, I., Beck, H., Lie, A. A., & Wiestler, O. D. (1999) · Epilepsy Research · doi:10.1016/s0920-1211(99)00052-2 · Cited by 188
“Several lines of evidence suggest that the hippocampal formation is critically involved in MTLE: (1) recordings from intracerebrally implanted electrodes often identify the onset of electrographic abnormalities within this structure (Van Roost et al., 1998).”
BackgroundBlümcke, I., Schewe, J., Normann, S., Brüstle, O., Schramm, J., Elger, C. E., & Wiestler, O. D. (2001) · Hippocampus · doi:10.1002/hipo.1045 · Cited by 187
“The epileptogenic focus was localized to the temporal lobe by noninvasive or invasive diagnostic procedures, as described elsewhere (Van Roost et al., 1998; Zentner et al., 1995).”
MethodSelf-citationAxmacher, N., Cohen, M. X., Fell, J., Haupt, S., Dümpelmann, M., Elger, C. E., Schlaepfer, T. E., Lenartz, D., Sturm, V., & Ranganath, C. (2010) · Neuron · doi:10.1016/j.neuron.2010.02.006 · Cited by 183
“All patients had bilateral hippocampal depth electrodes that were implanted for diagnostic purposes using a computerized tomography-based stereotactic insertion technique (Van Roost et al., 1998).”
MethodNeural Bases of Cognitive ERPs: More than Phase Reset
Fell, J., Dietl, T., Grunwald, T., Kurthen, M., Klaver, P., Trautner, P., Schaller, C., Elger, C. E., & Fernández, G. (2004) · Journal of Cognitive Neuroscience · doi:10.1162/0898929042568514 · Cited by 180
Andrzejak, R. G., Widman, G., Lehnertz, K., Rieke, C., David, P., & Elger, C. E. (2001) · Epilepsy Research · doi:10.1016/s0920-1211(01)00195-4 · Cited by 169
“Comparing only homologous recording regions for individual patients, higher values were calculated for EEGs recorded from mesial temporal structures of the focal hemisphere in all investigated cases (cf. Fig.”
BackgroundMethodYilmazer-Hanke, D. M., Wolf, H. K., Schramm, J., Elger, C. E., Wiestler, O. D., & Blümcke, I. (2000) · Journal of Neuropathology & Experimental Neurology · doi:10.1093/jnen/59.10.907 · Cited by 165
“The epileptogenic focus was localized to the temporal lobe in all patients by noninvasive and invasive diagnostic procedures as described elsewhere (42, 43).”
MethodSelf-citationRhinal–hippocampal EEG coherence is reduced during human sleep
Fell, J., Staedtgen, M., Burr, W., Kockelmann, E., Helmstaedter, C., Schaller, C., Elger, C. E., & Fernández, G. (2003) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2003.02934.x · Cited by 38
Enhancement of Neocortical-Medial Temporal EEG Correlations during Non-REM Sleep
Axmacher, N., Helmstaedter, C., Elger, C. E., & Fell, J. (2008) · Neural Plasticity · doi:10.1155/2008/563028 · Cited by 22
Metadata
- Authors
- Van Roost, D., Solymosi, L., Schramm, J., van Oosterwyck, B., & Eiger, C. E.
- Venue
- Neurosurgery
- Published
- 1998-10
- Volume
- 43
- Issue
- 4
- Pages
- 819-826
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2023081579
- Cited by
- 114
- References
- 0
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.