Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 221

The DOI matches its Crossref record.

Magnetic Resonance Imaging-based Stereotactic Localization of the Globus Pallidus and Subthalamic Nucleus

Starr, Philip A., Vitek, Jerrold L., DeLong, Mahlon, Bakay, Roy A.E.·1999·Neurosurgery

Abstract

OBJECTIVE: To optimize the accuracy of initial stereotactic targeting for movement disorders surgery, we performed stereotactic localization of the internal segment of the globus pallidus (GPi) and subthalamic nucleus (STN) using magnetic resonance imaging protocols in which the borders of these nuclei were directly visualized. METHODS: Fifty-one consecutive cases using the pallidal target and six using the subthalamic target were studied. Localization of these nuclei was performed using the Leksell stereotactic head frame and inversion recovery sequences (GPi) or T2-weighted spin echo sequences (STN). Targeting accuracy and individual variation in the spatial coordinates of these structures were independently measured by identification of nuclear boundaries during multiple microelectrode penetrations. RESULTS: The lateral and vertical coordinates of an atlas-defined point in the GPi, with respect to the line between the anterior and posterior commissures, was highly variable. Initial targeting the GPi based on direct visualization of the target boundaries (external medullary lamina and optic tract) resulted in greater precision than would be expected using fixed anterior and posterior commissure-based coordinates. Initial targeting the STN using magnetic resonance imaging was sufficiently precise to place the initial microelectrode penetration within STN in all six cases. CONCLUSION: Magnetic resonance imaging-based initial stereotactic targeting of the GPi, based on direct visualization of the target boundaries, is useful to improve target accuracy over that of purely indirect anterior and posterior commissure-based targeting methods. Initial targeting of the STN was reliably accomplished by direct visualization. However, there remains sufficient variability that the final target location in both GPi and STN required electrophysiological mapping in all cases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-199902000-00031

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 221

Metadata

Authors
Starr, P. A., Vitek, J. L., DeLong, M., & Bakay, R. A. E.
Venue
Neurosurgery
Published
1999-02-01
Volume
44
Issue
2
Pages
303-313
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2014258175
Cited by
221
References
0
FWCI
10.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic Resonance Imaging-based Stereotactic Localization of the Globus Pallidus and Subthalamic Nucleus. https://app.cochat.ai/papers/10.1097/00006123-199902000-00031
The paper
Starr, P. A., Vitek, J. L., DeLong, M., & Bakay, R. A. E. (1999). Magnetic Resonance Imaging-based Stereotactic Localization of the Globus Pallidus and Subthalamic Nucleus. Neurosurgery. https://doi.org/10.1097/00006123-199902000-00031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.