The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Electrophysiological mapping for the implantation of deep brain stimulators for Parkinson's disease and tremor
Open accessAbstract
The vast majority of centers use electrophysiological mapping techniques to finalize target selection during the implantation of deep brain stimulation (DBS) leads for the treatment of Parkinson's disease and tremor. This review discusses the techniques used for physiological mapping and addresses the questions of how various mapping strategies modify target selection and outcome following subthalamic nucleus (STN), globus pallidus internus (GPi), and ventralis intermedius (Vim) deep brain stimulation. Mapping strategies vary greatly across centers, but can be broadly categorized into those that use microelectrode or semimicroelectrode techniques to optimize position prior to implantation and macrostimulation through a macroelectrode or the DBS lead, and those that rely solely on macrostimulation and its threshold for clinical effects (benefits and side effects). Microelectrode criteria for implantation into the STN or GPi include length of the nucleus recorded, presence of movement-responsive neurons, and/or distance from the borders with adjacent structures. However, the threshold for the production of clinical benefits relative to side effects is, in most centers, the final, and sometimes only, determinant of DBS electrode position. Macrostimulation techniques for mapping, the utility of microelectrode mapping is reflected in its modification of electrode position in 17% to 87% of patients undergoing STN DBS, with average target adjustments of 1 to 4 mm. Nevertheless, with the absence of class I data, and in consideration of the large number of variables that impact clinical outcome, it is not possible to conclude that one technique is superior to the other in so far as motor Unified Parkinson's Disease Rating Scale outcome is concerned. Moreover, mapping technique is only one out of many variables that determine the outcome. The increase in surgical risk of intracranial hemorrhage correlated to the number of microelectrode trajectories must be considered against the risk of suboptimal benefits related to omission of this technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alexander, G. E., Crutcher, M. D., & DeLong, M. R. (1990) · PubMed · Cited by 2,442
Krack, P., Batir, A., Van Blercom, N., Chabardes, S., Fraix, V., Ardouin, C., Koudsie, A., Limousin, P. D., Benazzouz, A., LeBas, J. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035275 · Cited by 2,249
Self-citationWhich elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
(1991) · Progress in Brain Research · doi:10.1016/s0079-6123(08)62678-3 · Cited by 1,961
Electrical Stimulation of the Subthalamic Nucleus in Advanced Parkinson's Disease
Limousin, P., Krack, P., Pollak, P., Benazzouz, A., Ardouin, C., Hoffmann, D., & Benabid, A.-L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199810153391603 · Cited by 1,853
Self-citationEffect on parkinsonian signs and symptoms of bilateral subthalamic nucleus stimulation
Limousin, P., Pollak, P., Benazzouz, A., Hoffmann, D., Le Bas, J.-F., Perret, J. E., Benabid, A.-L., & Broussolle, E. (1995) · The Lancet · doi:10.1016/s0140-6736(95)90062-4 · Cited by 1,392
Self-citationBenabid, A. L., Pollak, P., Gao, D., Hoffmann, D., Limousin, P., Gay, E., Payen, I., & Benazzouz, A. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.84.2.0203 · Cited by 1,134
Self-citationA Comparison of Continuous Thalamic Stimulation and Thalamotomy for Suppression of Severe Tremor
Schuurman, P. R., Bosch, D. A., Bossuyt, P. M. M., Bonsel, G. J., van Someren, E. J. W., de Bie, R. M. A., Merkus, M. P., & Speelman, J. D. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420703 · Cited by 1,044
Tungsten Microelectrode for Recording from Single Units
Hubel, D. H. (1957) · Science · doi:10.1126/science.125.3247.549 · Cited by 849
Neurophysiological identification of the subthalamic nucleus in surgery for Parkinson's disease
Hutchison, W. D., Allan, R. J., Opitz, H., Levy, R., Dostrovsky, J. O., Lang, A. E., & Lozano, A. M. (1998) · Annals of Neurology · doi:10.1002/ana.410440407 · Cited by 702
Cited by
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Self-citationZaidel, A., Spivak, A., Grieb, B., Bergman, H., & Israel, Z. (2010) · Brain · doi:10.1093/brain/awq144 · Cited by 305
Resting tremor classification and detection in Parkinson's disease patients
Camara, C., Isasi, P., Warwick, K., Ruiz, V., Aziz, T., Stein, J., & Bakštein, E. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.09.006 · Cited by 70
Deep brain stimulation for essential tremor
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-53497-2.00013-9 · Cited by 38
Metadata
- Authors
- Gross, R. E., Krack, P., Rodriguez-Oroz, M. C., Rezai, A. R., & Benabid, A.-L.
- Venue
- Movement Disorders
- Publisher
- Wiley
- Published
- 2006
- Volume
- 21
- Issue
- S14
- Pages
- S259-S283
- ISSN
- 0885-3185 (ISSN-L)
- 1531-8257
- OpenAlex
- W2156785179
- Cited by
- 324
- References
- 114
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrophysiological mapping for the implantation of deep brain stimulators for Parkinson's disease and tremor. https://app.cochat.ai/papers/10.1002/mds.20960
- The paper
- Gross, R. E., Krack, P., Rodriguez-Oroz, M. C., Rezai, A. R., & Benabid, A.-L. (2006). Electrophysiological mapping for the implantation of deep brain stimulators for Parkinson's disease and tremor. Movement Disorders. https://doi.org/10.1002/mds.20960
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.