The DOI matches its Crossref record.
Stereotactic Navigation for Placement of Pedicle Screws in the Thoracic Spine
Abstract
OBJECTIVE: Pedicle screw fixation in the lumbar spine has become the standard of care for various causes of spinal instability. However, because of the smaller size and more complex morphology of the thoracic pedicle, screw placement in the thoracic spine can be extremely challenging. In several published series, cortical violations have been reported in up to 50% of screws placed with standard fluoroscopic techniques. The goal of this study is to evaluate the accuracy of thoracic pedicle screw placement by use of image-guided techniques. METHODS: During the past 4 years, 266 image-guided thoracic pedicle screws were placed in 65 patients at the University of Michigan Medical Center. Postoperative thin-cut computed tomographic scans were obtained in 52 of these patients who were available to enroll in the study. An impartial neuroradiologist evaluated 224 screws by use of a standardized grading scheme. All levels of the thoracic spine were included in the study. RESULTS: Chart review revealed no incidence of neurological, cardiovascular, or pulmonary injury. Of the 224 screws reviewed, there were 19 cortical violations (8.5%). Eleven (4.9%) were Grade II (≤2 mm), and eight (3.6%) were Grade III (>2 mm) violations. Only five screws (2.2%), however, were thought to exhibit unintentional, structurally significant violations. Statistical analysis revealed a significantly higher rate of cortical perforation in the midthoracic spine (T4–T8, 16.7%; T1–T4, 8.8%; and T9–T12, 5.6%). CONCLUSION: The low rate of cortical perforations (8.5%) and structurally significant violations (2.2%) in this retrospective series compares favorably with previously published results that used anatomic landmarks and intraoperative fluoroscopy. This study provides further evidence that stereotactic placement of pedicle screws can be performed safely and effectively at all levels of the thoracic spine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Free Hand Pedicle Screw Placement in the Thoracic Spine: Is it Safe?
Kim, Y. J., Lenke, L. G., Bridwell, K. H., Cho, Y. S., & Riew, K. D. (2004) · Spine · doi:10.1097/01.brs.0000109983.12113.9b · Cited by 706
Rajasekaran, S., Vidyadhara, S., Ramesh, P., & Shetty, A. P. (2007) · Spine · doi:10.1097/01.brs.0000252094.64857.ab · Cited by 358
Gautschi, O. P., Schatlo, B., Schaller, K., & Tessitore, E. (2011) · Neurosurgical Focus · doi:10.3171/2011.7.focus11168 · Cited by 268
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
Metadata
- Authors
- Youkilis, A. S., Quint, D. J., McGillicuddy, J. E., & Papadopoulos, S. M.
- Venue
- Neurosurgery
- Published
- 2001-04-01
- Volume
- 48
- Issue
- 4
- Pages
- 771-779
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2048824698
- Cited by
- 232
- References
- 0
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stereotactic Navigation for Placement of Pedicle Screws in the Thoracic Spine. https://app.cochat.ai/papers/10.1097/00006123-200104000-00015
- The paper
- Youkilis, A. S., Quint, D. J., McGillicuddy, J. E., & Papadopoulos, S. M. (2001). Stereotactic Navigation for Placement of Pedicle Screws in the Thoracic Spine. Neurosurgery. https://doi.org/10.1097/00006123-200104000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.