The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Randomized Clinical Study to Compare the Accuracy of Navigated and Non-Navigated Thoracic Pedicle Screws in Deformity Correction Surgeries
Abstract
STUDY DESIGN: Randomized clinical trial (level I evidence). OBJECTIVE: To compare the accuracy of non-navigation and Iso-C based navigation in pedicle screw fixation in thoracic spine deformities. SUMMARY OF BACKGROUND DATA: Thoracic pedicle screw insertion for spinal deformity correction can be associated with increased pedicle breaches. Iso-C based navigation has been reported to improve the accuracy of pedicle screw placement, but its use in the presence of deformity has not been reported. METHODS: Twenty-seven patients with scoliosis and 6 patients with kyphosis had a total of 478 thoracic pedicle screws. The average Cobb angle was 58.4 degrees +/- 8 degrees (range 50 degrees -80 degrees), and the mean kyphotic angle was 54.6 degrees +/- 4 degrees (range 51 degrees -76 degrees). By random allocation, 17 patients had screw insertion under navigation (242 screws) and 16 under fluoroscopic control (236 screws). The 2 groups were compared for accuracy of screw placement, time for screw insertion, and the number of times the C-arm had to be brought into the field. Two independent blinded observers determined accuracy using postoperative computed tomography assessments. RESULTS: There were 54 (23%) pedicle breaches in the non-navigation group as compared to only 5 (2%) in the navigation group (P < 0.001). Thirty-eight screws (16%) in the non-navigation group had penetrated the anterior or lateral cortex compared to 2 screws (0.8%) in the navigation group. Average screw insertion time in the non-navigation group was 4.61 +/- 1.05 minutes (range 1.8-6.5) compared to 2.37 +/- 0.72 minutes (range 1.16-4.5) in navigation group (P < 0.01). The C-arm had to be moved into the operation field on an average of 1.5 +/- 0.25 times (range 1-3) per screw. With single screening data, an average of 11.4 pedicles (range 9-14) could be visualized without necessity to bring the C-arm into operating field again. CONCLUSIONS: Iso-C navigation increases accuracy, and reduces surgical time and radiation in thoracic deformity correction surgeries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of Pedicular Screw Placement In Vivo
GERTZBEIN, S. D., & ROBBINS, S. E. (1990) · Spine · doi:10.1097/00007632-199001000-00004 · Cited by 1,381
Internal Fixation of the Lumbar Spine with Pedicle Screw Plating
ROY-CAMILLE, R., SAILLANT, G., & MAZEL, C. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198602000-00003 · Cited by 768
Free Hand Pedicle Screw Placement in the Thoracic Spine: Is it Safe?
Kim, Y. J., Lenke, L. G., Bridwell, K. H., Cho, Y. S., & Riew, K. D. (2004) · Spine · doi:10.1097/01.brs.0000109983.12113.9b · Cited by 706
Esses, S. I., Sachs, B. L., & Dreyzin, V. (1993) · Spine · doi:10.1097/00007632-199311000-00015 · Cited by 706
WEINSTEIN, J. N., SPRATT, K. F., SPENGLER, D., BRICK, C., & REID, S. (1988) · Spine · doi:10.1097/00007632-198809000-00008 · Cited by 532
Thoracic Human Vertebrae Quantitative Three-Dimensional Anatomy
PANJABI, M. M., TAKATA, K., GOEL, V., FEDERICO, D., OXLAND, T., DURANCEAU, J., & KRAG, M. (1991) · SPINE · doi:10.1097/00007632-199108000-00006 · Cited by 396
Accuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis
Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.-P., & Ozdoba, C. (1997) · Spine · doi:10.1097/00007632-199702150-00020 · Cited by 284
Laine, T., Schlenzka, D., Mäkitalo, K., Tallroth, K., Nolte, L.-P., & Visarius, H. (1997) · Spine · doi:10.1097/00007632-199706010-00018 · Cited by 277
Pedicle Screw Placement Using Image Guided Techniques
Merloz, P., Tonetti, J., Pittet, L., Coulomb, M., Lavalle??, S., & Sautot, P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00006 · Cited by 260
Application of frameless stereotaxy to pedicle screw fixation of the spine
Kalfas, I. H., Kormos, D. W., Murphy, M. A., McKenzie, R. L., Barnett, G. H., Bell, G. R., Steiner, C. P., Trimble, M. B., & Weisenberger, J. P. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.4.0641 · Cited by 247
Cited by
Worldwide Survey on the Use of Navigation in Spine Surgery
Härtl, R., Lam, K. S., Wang, J., Korge, A., Kandziora, F., & Audigé, L. (2013) · World Neurosurgery · doi:10.1016/j.wneu.2012.03.011 · Cited by 270
Muthu, S., & Ramakrishnan, E. (2021) · Spine · doi:10.1097/brs.0000000000003645 · Cited by 30
Metadata
- Authors
- Rajasekaran, S., Vidyadhara, S., Ramesh, P., & Shetty, A. P.
- Venue
- Spine
- Published
- 2007-01
- Volume
- 32
- Issue
- 2
- Pages
- E56-E64
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2081494650
- Cited by
- 358
- References
- 28
- FWCI
- 15.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Randomized Clinical Study to Compare the Accuracy of Navigated and Non-Navigated Thoracic Pedicle Screws in Deformity Correction Surgeries. https://app.cochat.ai/papers/10.1097/01.brs.0000252094.64857.ab
- The paper
- Rajasekaran, S., Vidyadhara, S., Ramesh, P., & Shetty, A. P. (2007). Randomized Clinical Study to Compare the Accuracy of Navigated and Non-Navigated Thoracic Pedicle Screws in Deformity Correction Surgeries. Spine. https://doi.org/10.1097/01.brs.0000252094.64857.ab
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.