The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Image-guided Hypo-fractionated Stereotactic Radiosurgery to Spinal Lesions
Abstract
OBJECTIVE: This article demonstrates the technical feasibility of noninvasive treatment of unresectable spinal vascular malformations and primary and metastatic spinal tumors by use of image-guided frameless stereotactic radiosurgery. METHODS: Stereotactic radiosurgery delivers a high dose of radiation to a tumor volume or vascular malformation in a limited number of fractions and minimizes the dose to adjacent normal structures. Frameless image-guided radiosurgery was developed by coupling an orthogonal pair of x-ray cameras to a dynamically manipulated robot-mounted linear accelerator that guides the therapy beam to treatment sites within the spine or spinal cord, in an outpatient setting, and without the use of frame-based fixation. The system relies on skeletal landmarks or implanted fiducial markers to locate treatment targets. Sixteen patients with spinal lesions (hemangioblastomas, vascular malformations, metastatic carcinomas, schwannomas, a meningioma, and a chordoma) were treated with total treatment doses of 1100 to 2500 cGy in one to five fractions by use of image-guided frameless radiosurgery with the CyberKnife system (Accuray, Inc., Sunnyvale, CA). Thirteen radiosurgery plans were analyzed for compliance with conventional radiation therapy. RESULTS: Tests demonstrated alignment of the treatment dose with the target volume within ± 1 mm by use of spine fiducials and the CyberKnife treatment planning system. Tumor patients with at least 6 months of follow-up have demonstrated no progression of disease. Radiographic follow-up is pending for the remaining patients. To date, no patients have experienced complications as a result of the procedure. CONCLUSION: This experience demonstrates the feasibility of image-guided robotic radiosurgery for previously untreatable spinal lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The stereotaxic method and radiosurgery of the brain.
Leksell, L. G. (1951) · PubMed · Cited by 1,408
Radiation therapy oncology group: Radiosurgery quality assurance guidelines
Shaw, E., Kline, R., Gillin, M., Souhami, L., Hirschfeld, A., Dinapoli, R., & Martin, L. (1993) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(93)90548-a · Cited by 748
The Cyberknife: A Frameless Robotic System for Radiosurgery
Adler Jr., J. R., Chang, S. D., Murphy, M. J., Doty, J., Geis, P., & Hancock, S. L. (1997) · Stereotactic and Functional Neurosurgery · doi:10.1159/000099863 · Cited by 671
Self-citationRadiation response of the central nervous system
Schultheiss, T. E., Kun, L. E., Ang, K. K., & Stephens, L. C. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(94)00655-5 · Cited by 653
Image-guided Robotic Radiosurgery
Adler, J. R., Murphy, M. J., Chang, S. D., & Hancock, S. L. (1999) · Neurosurgery · doi:10.1097/00006123-199906000-00079 · Cited by 412
Self-citationThe Application Accuracy of Stereotactic Frames
Maciunas, R. J., Galloway, R. L., & Latimer, J. W. (1994) · Neurosurgery · doi:10.1227/00006123-199410000-00015 · Cited by 395
Robotic motion compensation for respiratory movement during radiosurgery
Schweikard, A., Glosser, G., Bodduluri, M., Murphy, M. J., & Adler, J. R. (2000) · Computer Aided Surgery · doi:10.1002/1097-0150(2000)5:4<263::aid-igs5>3.0.co;2-2 · Cited by 393
Self-citationThe incidence of myelitis after irradiation of the cervical spinal cord
Marcus, R. B., & Million, R. R. (1990) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(90)90126-5 · Cited by 239
Murphy, M. J. (1997) · Medical Physics · doi:10.1118/1.598005 · Cited by 171
Self-citationImage-Guided Radiosurgery for the Spine and Pancreas
Murphy, M. J., Adler, J. R., Bodduluri, M., Dooley, J., Forster, K. M., Hai, J. O., Le, Q., Luxton, G., Martin, D. P., & Poen, J. C. (2000) · Computer Aided Surgery · doi:10.1002/1097-0150(2000)5:4<278::aid-igs6>3.0.co;2-k · Cited by 147
Self-citation
Cited by
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Benedict, S. H., Yenice, K. M., Followill, D., Galvin, J. M., Hinson, W., Kavanagh, B., Keall, P., Lovelock, M., Meeks, S., Papiez, L., et al. (2010) · Medical Physics · doi:10.1118/1.3438081 · Cited by 2,218
Cox, B. W., Spratt, D. E., Lovelock, M., Bilsky, M. H., Lis, E., Ryu, S., Sheehan, J., Gerszten, P. C., Chang, E., Gibbs, I., et al. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2012.03.009 · Cited by 609
Self-citationGerszten, P. C., Mendel, E., & Yamada, Y. (2009) · Spine · doi:10.1097/brs.0b013e3181b8b6f5 · Cited by 343
Image Similarity Using Mutual Information of Regions
Russakoff, D. B., Tomasi, C., Rohlfing, T., & Maurer, C. R. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24672-5_47 · Cited by 286
Russakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
Self-citation
Metadata
- Authors
- Ryu, S. I., Chang, S. D., Kim, D. H., Murphy, M. J., Le, Q.-T., Martin, D. P., & Adler, J. R.
- Venue
- Neurosurgery
- Published
- 2001-10-01
- Volume
- 49
- Issue
- 4
- Pages
- 838-846
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W1969919385
- Cited by
- 344
- References
- 13
- FWCI
- 21.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Image-guided Hypo-fractionated Stereotactic Radiosurgery to Spinal Lesions. https://app.cochat.ai/papers/10.1097/00006123-200110000-00011
- The paper
- Ryu, S. I., Chang, S. D., Kim, D. H., Murphy, M. J., Le, Q.-T., Martin, D. P., & Adler, J. R. (2001). Image-guided Hypo-fractionated Stereotactic Radiosurgery to Spinal Lesions. Neurosurgery. https://doi.org/10.1097/00006123-200110000-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.