Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 395

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

The Application Accuracy of Stereotactic Frames

Maciunas, Robert J., Galloway, Robert L., Latimer, Jim W. · 1994 · Neurosurgery

Abstract

The purpose of incorporating stereotactic methodology into neurosurgical operations is to achieve a consistently high degree of accuracy in localizing intracranial targets. Therefore, the limits of resolution for the operation are a function of the accuracy of the particular stereotactic frame system. The total clinically relevant error (application accuracy) comprises errors associated with each procedural step, including imaging, target selection, vector calculations, and the mechanical errors of stereotactic frames. To evaluate these parameters, a systematic error analysis was carried out with four commonly used stereotactic devices: the Brown-Roberts-Wells, the Cosman-Roberts-Wells, the Kelly-Goerss COMPASS (modified Todd-Wells), and the Leksell frames. Over 21,500 independent accuracy test measurements were made with 11,000 computed tomograms. The results suggest a potentially significant degree of error in the application accuracy of all stereotactic instruments, which is accentuated by but not entirely due to imaging-associated errors. Clinically encountered levels of weightbearing by stereotactic frames may have a pronounced effect on their mechanical accuracy. Both the reapplication of aiming arc assemblies and the use of phantom base units introduce independent sources of mechanical inaccuracy into stereotactic procedures. The scope of individual error values and their determining factors must be considered with every clinical use of stereotactic frame systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/00006123-199410000-00015

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 395

Metadata

Authors
Maciunas, R. J., Galloway, R. L., & Latimer, J. W.
Venue
Neurosurgery
Published
1994-10-01
Volume
35
Issue
4
Pages
682-695
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2017417414
Cited by
395
References
14
FWCI
5.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Application Accuracy of Stereotactic Frames. https://app.cochat.ai/papers/10.1227/00006123-199410000-00015
The paper
Maciunas, R. J., Galloway, R. L., & Latimer, J. W. (1994). The Application Accuracy of Stereotactic Frames. Neurosurgery. https://doi.org/10.1227/00006123-199410000-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.