The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
The Application Accuracy of Stereotactic Frames
Abstract
The purpose of incorporating stereotactic methodology into neurosurgical operations is to achieve a consistently high degree of accuracy in localizing intracranial targets. Therefore, the limits of resolution for the operation are a function of the accuracy of the particular stereotactic frame system. The total clinically relevant error (application accuracy) comprises errors associated with each procedural step, including imaging, target selection, vector calculations, and the mechanical errors of stereotactic frames. To evaluate these parameters, a systematic error analysis was carried out with four commonly used stereotactic devices: the Brown-Roberts-Wells, the Cosman-Roberts-Wells, the Kelly-Goerss COMPASS (modified Todd-Wells), and the Leksell frames. Over 21,500 independent accuracy test measurements were made with 11,000 computed tomograms. The results suggest a potentially significant degree of error in the application accuracy of all stereotactic instruments, which is accentuated by but not entirely due to imaging-associated errors. Clinically encountered levels of weightbearing by stereotactic frames may have a pronounced effect on their mechanical accuracy. Both the reapplication of aiming arc assemblies and the use of phantom base units introduce independent sources of mechanical inaccuracy into stereotactic procedures. The scope of individual error values and their determining factors must be considered with every clinical use of stereotactic frame systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Statistical Analysis.
Latshaw, V. V., Dixon, W. J., & Massey, F. J. (1957) · The American Mathematical Monthly · doi:10.2307/2309989 · Cited by 5,072
Glantz, S. A. (1981) · Cited by 2,636
The stereotaxic method and radiosurgery of the brain.
Leksell, L. G. (1951) · PubMed · Cited by 1,408
Stereotaxic Apparatus for Operations on the Human Brain
Spiegel, E. A., Wycis, H. T., Marks, M., & Lee, A. J. (1947) · Science · doi:10.1126/science.106.2754.349 · Cited by 982
THE STRUCTURE AND FUNCTIONS OF THE CEREBELLUM EXAMINED BY A NEW METHOD.
HORSLEY, V., & CLARKE, R. H. (1908) · Brain · doi:10.1093/brain/31.1.45 · Cited by 783
A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope
Roberts, D. W., Strohbehn, J. W., Hatch, J. F., Murray, W. T., & Kettenberger, H. (1986) · Journal of neurosurgery · doi:10.3171/jns.1986.65.4.0545 · Cited by 640
Introduction to Statistical Analysis.
Dixon, W. J., & Jr., J. M. (1957) · Biometrika · doi:10.2307/2332898 · Cited by 440
Interactive image-guided neurosurgery
Galloway, R. L., Maciunas, R. J., & Edwards, C. A. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.184698 · Cited by 229
Self-citationLinear accelerator radiosurgery for arteriovenous malformations
Friedman, W. A., & Bova, F. J. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.6.0832 · Cited by 222
A computerized tomography-computer graphics approach to stereotaxic localization
Brown, R. A. (1979) · Journal of Neurosurgery · doi:10.3171/jns.1979.50.6.0715 · Cited by 205
Cited by
Cardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., et al. (2013) · Neurosurgery · doi:10.1227/neu.0b013e31827d1161 · Cited by 527
Patient-specific analysis of the volume of tissue activated during deep brain stimulation
Butson, C. R., Cooper, S. E., Henderson, J. M., & McIntyre, C. C. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.034 · Cited by 489
Starr, P. A., Christine, C. W., Theodosopoulos, P. V., Lindsey, N., Byrd, D., Mosley, A., & Marks, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.2.0370 · Cited by 415
Image-guided Robotic Radiosurgery
Adler, J. R., Murphy, M. J., Chang, S. D., & Hancock, S. L. (1999) · Neurosurgery · doi:10.1097/00006123-199906000-00079 · Cited by 412
Image-guided Hypo-fractionated Stereotactic Radiosurgery to Spinal Lesions
Ryu, S. I., Chang, S. D., Kim, D. H., Murphy, M. J., Le, Q.-T., Martin, D. P., & Adler, J. R. (2001) · Neurosurgery · doi:10.1097/00006123-200110000-00011 · Cited by 344
Metadata
- Authors
- Maciunas, R. J., Galloway, R. L., & Latimer, J. W.
- Venue
- Neurosurgery
- Published
- 1994-10-01
- Volume
- 35
- Issue
- 4
- Pages
- 682-695
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2017417414
- Cited by
- 395
- References
- 14
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Application Accuracy of Stereotactic Frames. https://app.cochat.ai/papers/10.1227/00006123-199410000-00015
- The paper
- Maciunas, R. J., Galloway, R. L., & Latimer, J. W. (1994). The Application Accuracy of Stereotactic Frames. Neurosurgery. https://doi.org/10.1227/00006123-199410000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.