Measurement of Cerebrospinal Fluid Flow at the Cerebral Aqueduct by Use of Phase-contrast Magnetic Resonance Imaging: Technique Validation and Utility in Diagnosing Idiopathic Normal Pressure Hydrocephalus

Luetmer, Patrick H., Huston, John, Friedman, Jonathan A., Dixon, Geoffrey R., Petersen, Ronald C., Jack, Clifford R., McClelland, Robyn L., Ebersold, Michael J.·2002·Neurosurgery

Abstract

OBJECTIVE: We analyzed the reliability of a protocol for measuring quantitative cerebrospinal fluid (CSF) flow at the cerebral aqueduct and established the range of CSF flows in normal elderly patients, patients with Alzheimer's and other forms of dementia, and patients with idiopathic normal pressure hydrocephalus (NPH). METHODS: A constant flow phantom was used to establish the accuracy of the CSF flow measurement. The clinical variability of the measurement was estimated by calculating the standard deviations and coefficients of variation of intra- and interobserver and intertrial data sets derived from three normal volunteers. A total of 236 patients were studied, including 47 normal elderly patients, 115 patients with cognitive impairment (9 with mild cognitive impairment, 46 with Alzheimer's disease, and 60 with other cognitive impairment), 31 patients in whom NPH was suspected but ultimately excluded, and 43 patients with a final clinical diagnosis of NPH. RESULTS: The intraobserver, interobserver, and intertrial measurement variations of 6.4, 5.4, and 8.8%, respectively, were substantially smaller than the wide variation observed among subjects. There was no statistically significant difference in flow between normal elderly patients and patients with cognitive impairment (P = 0.91). When these populations were pooled, the average flow was 8.47 ml/min (standard deviation, 4.23; range, 0.9-18.5 ml/min). The average flow rate in patients with a final clinical diagnosis of NPH was 27.4 ml/min (standard deviation, 15.3; range, 3.13-62.2 ml/min). This was significantly higher than the flow rate in each of the other three groups (all, P < 0.001). CONCLUSION: CSF flow measurements of less than 18 ml/min with a sinusoidal flow pattern are normal. CSF flow of greater than 18 ml/min suggests idiopathic NPH.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-200203000-00020

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 198

Metadata

Authors
Luetmer, P. H., Huston, J., Friedman, J. A., Dixon, G. R., Petersen, R. C., Jack, C. R., McClelland, R. L., & Ebersold, M. J.
Venue
Neurosurgery
Published
2002-03-01
Volume
50
Issue
3
Pages
534-543
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2024187026
Cited by
198
References
0
FWCI
1.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Cerebrospinal Fluid Flow at the Cerebral Aqueduct by Use of Phase-contrast Magnetic Resonance Imaging: Technique Validation and Utility in Diagnosing Idiopathic Normal Pressure Hydrocephalus. https://app.cochat.ai/papers/10.1097/00006123-200203000-00020
The paper
Luetmer, P. H., Huston, J., Friedman, J. A., Dixon, G. R., Petersen, R. C., Jack, C. R., McClelland, R. L., & Ebersold, M. J. (2002). Measurement of Cerebrospinal Fluid Flow at the Cerebral Aqueduct by Use of Phase-contrast Magnetic Resonance Imaging: Technique Validation and Utility in Diagnosing Idiopathic Normal Pressure Hydrocephalus. Neurosurgery. https://doi.org/10.1097/00006123-200203000-00020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.