Measurement of Cerebrospinal Fluid Flow at the Cerebral Aqueduct by Use of Phase-contrast Magnetic Resonance Imaging: Technique Validation and Utility in Diagnosing Idiopathic Normal Pressure Hydrocephalus
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We analyzed the reliability of a protocol for measuring quantitative cerebrospinal fluid (CSF) flow at the cerebral aqueduct and established the range of CSF flows in normal elderly patients, patients with Alzheimer's and other forms of dementia, and patients with idiopathic normal pressure hydrocephalus (NPH). METHODS: A constant flow phantom was used to establish the accuracy of the CSF flow measurement. The clinical variability of the measurement was estimated by calculating the standard deviations and coefficients of variation of intra- and interobserver and intertrial data sets derived from three normal volunteers. A total of 236 patients were studied, including 47 normal elderly patients, 115 patients with cognitive impairment (9 with mild cognitive impairment, 46 with Alzheimer's disease, and 60 with other cognitive impairment), 31 patients in whom NPH was suspected but ultimately excluded, and 43 patients with a final clinical diagnosis of NPH. RESULTS: The intraobserver, interobserver, and intertrial measurement variations of 6.4, 5.4, and 8.8%, respectively, were substantially smaller than the wide variation observed among subjects. There was no statistically significant difference in flow between normal elderly patients and patients with cognitive impairment (P = 0.91). When these populations were pooled, the average flow was 8.47 ml/min (standard deviation, 4.23; range, 0.9-18.5 ml/min). The average flow rate in patients with a final clinical diagnosis of NPH was 27.4 ml/min (standard deviation, 15.3; range, 3.13-62.2 ml/min). This was significantly higher than the flow rate in each of the other three groups (all, P < 0.001). CONCLUSION: CSF flow measurements of less than 18 ml/min with a sinusoidal flow pattern are normal. CSF flow of greater than 18 ml/min suggests idiopathic NPH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic and Statistical Manual of Mental Disorders
Williams, J. B. W., & First, M. (2013) · Encyclopedia of Social Work · doi:10.1093/acrefore/9780199975839.013.104 · Cited by 109,519
McKhann, G., Drachman, D., Folstein, M., Katzman, R., Price, D., & Stadlan, E. M. (1984) · Neurology · doi:10.1212/wnl.34.7.939 · Cited by 27,915 · cited 1×
“The criteria for dementia were derived from the Diagnostic and Statistical Manual of Mental Disorders, 3rd revised edition (1), and those for AD were in accordance with the guidelines set forth by the National Institute of Neurological and Communicative Disorders and Stroke and the Alzheimer’s Disease and Related Diso…”
MethodDiagnostic and Statistical Manual of Mental Disorders
&NA; (1988) · Alzheimer Disease & Associated Disorders · doi:10.1097/00002093-198802020-00022 · Cited by 12,526
MR‐based hippocampal volumetry in the diagnosis of Alzheimer's disease
Jack, C. R., Petersen, R. C., O'Brien, P. C., & Tangalos, E. G. (1992) · Neurology · doi:10.1212/wnl.42.1.183 · Cited by 878 · cited 1×
“However, flow voids on T2-weighted images are dependent on magnetic field strength, slice thickness, TE, and motion compensation techniques, such as cardiac gating and gradient moment nulling, as well as differences between standard spin echo and fast spin echo pulse sequences (4, 18, 32).”
BackgroundSelf-citationNormal-pressure hydrocephalus: evaluation with cerebrospinal fluid flow measurements at MR imaging.
Bradley, W. G., Scalzo, D., Queralt, J., Nitz, W. N., Atkinson, D. J., & Wong, P. (1996) · Radiology · doi:10.1148/radiology.198.2.8596861 · Cited by 392 · cited 5×
“(24), and it is higher than the 42- l stroke volume associated with shunt-responsive NPH (5).”
BackgroundInfluentialHuman brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging.
Feinberg, D. A., & Mark, A. S. (1987) · Radiology · doi:10.1148/radiology.163.3.3575734 · Cited by 379 · cited 1×
“During CSF diastole, venous blood exits the cranial vault at a faster rate than arterial blood enters it, with a resultant net loss in intracranial blood volume and a reversal of CSF flow (3, 9, 12, 24, 27, 30).”
BackgroundEnzmann, D. R., & Pelc, N. J. (1991) · Radiology · doi:10.1148/radiology.178.2.1987610 · Cited by 364 · cited 2×
“This sinusoidal CSF flow pattern is modulated by complex brain motion, with a downward piston-like motion of the central structures, including the diencephalon, the brainstem, and the cerebellar tonsils during CSF diastole as well as radial compressive motion of the cerebral hemispheres and lateral compressive motion…”
BackgroundBrain parenchyma motion: measurement with cine echo-planar MR imaging.
Poncelet, B. P., Wedeen, V. J., Weisskoff, R. M., & Cohen, M. S. (1992) · Radiology · doi:10.1148/radiology.185.3.1438740 · Cited by 285 · cited 1×
“This sinusoidal CSF flow pattern is modulated by complex brain motion, with a downward piston-like motion of the central structures, including the diencephalon, the brainstem, and the cerebellar tonsils during CSF diastole as well as radial compressive motion of the cerebral hemispheres and lateral compressive motion…”
BackgroundBrain motion: measurement with phase-contrast MR imaging.
Enzmann, D. R., & Pelc, N. J. (1992) · Radiology · doi:10.1148/radiology.185.3.1438741 · Cited by 273 · cited 1×
“During CSF diastole, venous blood exits the cranial vault at a faster rate than arterial blood enters it, with a resultant net loss in intracranial blood volume and a reversal of CSF flow (3, 9, 12, 24, 27, 30).”
BackgroundNitz, W. R., Bradley, W. G., Watanabe, A. S., Lee, R. R., Burgoyne, B., O'Sullivan, R. M., & Herbst, M. D. (1992) · Radiology · doi:10.1148/radiology.183.2.1561340 · Cited by 273 · cited 7×
“(24), and it is higher than the 42- l stroke volume associated with shunt-responsive NPH (5).”
BackgroundMethodInfluential
Cited by
Guidelines for Management of Idiopathic Normal Pressure Hydrocephalus: Second Edition
MORI, E., ISHIKAWA, M., KATO, T., KAZUI, H., MIYAKE, H., MIYAJIMA, M., NAKAJIMA, M., HASHIMOTO, M., KURIYAMA, N., TOKUDA, T., et al. (2012) · Neurologia medico-chirurgica · doi:10.2176/nmc.52.775 · Cited by 666
The pulsating brain: A review of experimental and clinical studies of intracranial pulsatility
Wagshul, M. E., Eide, P. K., & Madsen, J. R. (2011) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-8-5 · Cited by 473
Marmarou, A., Bergsneider, M., Klinge, P., Relkin, N., & Black, P. M. (2005) · Neurosurgery · doi:10.1227/01.neu.0000168184.01002.60 · Cited by 469
Orešković, D., & Klarica, M. (2010) · Brain Research Reviews · doi:10.1016/j.brainresrev.2010.04.006 · Cited by 338
Aging Effects on Cerebral Blood and Cerebrospinal Fluid Flows
Stoquart-ElSankari, S., Balédent, O., Gondry-Jouet, C., Makki, M., Godefroy, O., & Meyer, M.-E. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600462 · Cited by 280
Cerebrospinal fluid flow imaging by using phase-contrast MR technique
Battal, B., Kocaoglu, M., Bulakbasi, N., Husmen, G., Tuba Sanal, H., & Tayfun, C. (2011) · The British Journal of Radiology · doi:10.1259/bjr/66206791 · Cited by 252
ISHIKAWA, M., HASHIMOTO, M., KUWANA, N., MORI, E., MIYAKE, H., WACHI, A., TAKEUCHI, T., KAZUI, H., & KOYAMA, H. (2008) · Neurologia medico-chirurgica · doi:10.2176/nmc.48.s1 · Cited by 251
The diagnosis and treatment of idiopathic normal pressure hydrocephalus
Gallia, G. L., Rigamonti, D., & Williams, M. A. (2006) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0237 · Cited by 228
Pathogenesis and pathophysiology of idiopathic normal pressure hydrocephalus
Wang, Z., Zhang, Y., Hu, F., Ding, J., & Wang, X. (2020) · CNS Neuroscience & Therapeutics · doi:10.1111/cns.13526 · Cited by 165
Coles, J. A., Myburgh, E., Brewer, J. M., & McMenamin, P. G. (2017) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2017.05.002 · Cited by 123
Metadata
- Authors
- Luetmer, P. H., Huston, J., Friedman, J. A., Dixon, G. R., Petersen, R. C., Jack, C. R., McClelland, R. L., & Ebersold, M. J.
- Venue
- Neurosurgery
- Published
- 2002-03-01
- Volume
- 50
- Issue
- 3
- Pages
- 534-543
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2024187026
- Cited by
- 198
- References
- 25
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.