CoChat

Subtraction ictal SPET co-registered to MRI in partial epilepsy: Description and technical validation of the method with phantom and patient studies

OʼBRIEN, TJ., OʼCONNOR, M. K., MULLAN, B. P., BRINKMANN, B. H., HANSON, D., JACK, C. R., SO, E. L. · 1998 · Nuclear Medicine Communications
Cited by 182

The DOI matches its Crossref record.

Abstract

Computer-aided subtraction of the co-registered and normalized interictal from the ictal single photon emission tomography (SPET) scan, followed by co-registration to the magnetic resonance image, may improve the utility of ictal SPET in the localization of partial epilepsy. This paper describes and technically validates our method. The SPET to SPET co-registration was tested using six sequential 99Tc(m) brain phantom SPET images of different known positions (15 matches). The registration error was determined by multiplying the calculated match transformation matrix by the inverse of the known transformation matrix. The 'worst case' co-registration error was less that one voxel diameter in all cases (median 3.2 mm, range 1.2-4.8 mm). For interictal to ictal SPET registrations in 10 consecutive intractable partial epilepsy patients, a similar root mean square distance (RMSD) between corresponding points on the matched scans was found as for the phantom studies (median 2.2 vs 2.6 mm). The appropriateness of our normalization was studied by comparing the pixel intensity distributions between the matched scans, and by analysing the subtraction pixel intensity distribution. The pixel intensity distribution for both the normalized phantom, and paired normalized patient studies, were closely matched to each other except for the extreme values, which in clinical situations likely represent regions of ictal activation or depression. The subtraction image intensity distributions were symmetrically centred on zero for all values up to at least within the 5th to 95th centile range, confirming good normalization for the 'non-activated' pixels. Also, a linear relationship was demonstrated between the measured pixel intensity on the phantom scans and the true changes in 99Tc(m) activity based on its decay constant. The results of this study demonstrate that our method produces accurate SPET to SPET co-registration, and appropriate SPET normalization, thereby allowing a valid ictal subtraction image to be derived.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006231-199801000-00006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
OʼBRIEN, T., OʼCONNOR, M. K., MULLAN, B. P., BRINKMANN, B. H., HANSON, D., JACK, C. R., & SO, E. L.
Venue
Nuclear Medicine Communications
Published
1998-01
Volume
19
Issue
1
Pages
31-46
ISSN
0143-3636 (ISSN-L)
OpenAlex
W2082185650
Cited by
182
References
0
FWCI
7.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subtraction ictal SPET co-registered to MRI in partial epilepsy: Description and technical validation of the method with phantom and patient studies. https://app.cochat.ai/papers/10.1097/00006231-199801000-00006
The paper
OʼBRIEN, T., OʼCONNOR, M. K., MULLAN, B. P., BRINKMANN, B. H., HANSON, D., JACK, C. R., & SO, E. L. (1998). Subtraction ictal SPET co-registered to MRI in partial epilepsy: Description and technical validation of the method with phantom and patient studies. Nuclear Medicine Communications. https://doi.org/10.1097/00006231-199801000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.