Subtraction peri-ictal SPECT is predictive of extratemporal epilepsy surgery outcome

O’Brien, T.J., So, E.L., Mullan, B.P., Cascino, G.D., Hauser, M.F., Brinkmann, B.H., Sharbrough, F.W., Meyer, F.B. · 2000 · Neurology

Abstract

OBJECTIVES: To determine whether localization of extratemporal epilepsy with subtraction ictal SPECT coregistered with MRI (SISCOM) is predictive of outcome after resective epilepsy surgery, whether SISCOM images provide prognostically important information compared with standard tests, and whether blood flow change on SISCOM images is useful in determining site and extent of excision required. BACKGROUND: The value of SISCOM in predicting surgical outcome for extratemporal epilepsy is unknown, especially if MRI findings are nonlocalizing. METHODS: SISCOM images in 36 consecutive patients were classified by blinded reviewers as "localizing and concordant with site of surgery," "localizing but nonconcordant with site of surgery," or "nonlocalizing." SISCOM images were coregistered with postoperative MRI, and reviewers visually determined whether cerebral cortex underlying the SISCOM focus had been completely resected, partially resected, or not resected. RESULTS: Twenty-four patients (66.7%) had localizing SISCOM, including 13 (76.5%) of those without a focal MRI lesion. Eleven of 19 patients (57.9%) with localizing SISCOM concordant with the surgical site, compared with 3 of 17 (17.6%) with nonlocalizing or nonconcordant SISCOM, had an excellent outcome (p < 0.05). With logistic regression analysis, SISCOM findings were predictive of postsurgical outcome, independently of MRI or scalp ictal EEG findings (p < 0.05). The extent of resection of the cortical region of the SISCOM focus was significantly associated with the rate of excellent outcome (100% with complete resection, 60% with partial resection, and 20% with nonresection, p < 0.05). CONCLUSION: SISCOM images may be useful in guiding the location and extent of resection in extratemporal epilepsy surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.55.11.1668

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 224

Metadata

Authors
O’Brien, T. J., So, E. L., Mullan, B. P., Cascino, G. D., Hauser, M. F., Brinkmann, B. H., Sharbrough, F. W., & Meyer, F. B.
Venue
Neurology
Published
2000-12-12
Volume
55
Issue
11
Pages
1668-1677
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W2060116265
Cited by
224
References
0
FWCI
5.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subtraction peri-ictal SPECT is predictive of extratemporal epilepsy surgery outcome. https://app.cochat.ai/papers/10.1212/wnl.55.11.1668
The paper
O’Brien, T. J., So, E. L., Mullan, B. P., Cascino, G. D., Hauser, M. F., Brinkmann, B. H., Sharbrough, F. W., & Meyer, F. B. (2000). Subtraction peri-ictal SPECT is predictive of extratemporal epilepsy surgery outcome. Neurology. https://doi.org/10.1212/wnl.55.11.1668

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.